Development of an Animal Fracture Model for Evaluation of Cement Augmentation Femoroplasty: An In Vitro Biomechanical Study

نویسندگان

  • Qiang Luo
  • William W. Lu
  • Tak-Wing Lau
  • Frankie Leung
چکیده

Osteoporotic hip fracture is the most severe kind of fracture with high morbidity and mortality. Patients' ambulation and quality of life are significantly affected by the fracture because only 50% regain their prefracture functional status, even if they undergo surgeries. There are many issues associated with the current preventive methods e.g., cost, side effects, patient compliance, and time for onset of action. Femoroplasty, the injection of bone cement into the proximal femur to augment femoral strength and to prevent fracture, has been an option with great potential. However, until now femoroplasty has remained at the stage of biomechanical testing. No in vivo study has evaluated its safety and effectiveness; there is not even an animal model for such investigations. The objective of this study was to develop a proximal femur fracture goat model that consistently fractures at the proximal femur when subject to vertical load, simulating osteoporotic hip fractures in human. Six pairs of fresh frozen mature Chinese goats' femora were obtained and randomly assigned into two groups. For the experimental group, a cylindrical bone defect was created at the proximal femur, while the control was left untreated. In addition, a configuration to mimic the mechanical axis of the goat femur was developed. When subjected to load along the mechanical axis, all the specimens from the bone defect group experienced femoral neck fractures, while fractures occurred at the femoral neck or other sites of the proximal femur in the control group. The biomechanical property (failure load) of the bone defect specimens was significantly lower than that of the control specimens (p<0.05). Osteoporotic hip fractures of humans were simulated by a goat fracture model, which may serve as a reference for future femoroplasty studies in vivo. The newly developed configuration simulating a femoral mechanical axis for biomechanical tests was practicable during the study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An image-guided femoroplasty system: Development and initial cadaver studies

This paper describes the development and initial cadaver studies using a prototype image-guided surgery system for femoroplasty, which is a potential alternative treatment for reducing fracture risk in patients with severe osteoporosis. Our goal is to develop an integrated surgical guidance system that will allow surgeons to augment the femur using patient-specific biomechanical planning and in...

متن کامل

Biomechanical Evaluation of Augmentation of Osteoporotic Cancellous Bone with an Injectable Nano-hydroxyapatite/ Polyamide 66 Composite Cement

A new injectable biomimetic composite cement composed of nano-hydroxyapatite (n-HA) and polyamide 66 (polyhexamethylene adipamide) has been developed. This study investigated that in vitro biomechanical performances of three n-HA/PA composite cements in the augmentation of osteoporotic cancellous bone were different in various n-HA content to evaluate the clinical applicability. The thoracic ve...

متن کامل

The Most Appropriate Reconstruction Method Following Giant Cell Tumor Curettage: A Biomechanical Approach

Giant cell tumor (GCT) is a primary and benign tumor of bone, albeit locally aggressive in some cases, such as in the epi-metaphyseal region of long bones, predominantly the distal end of femur and proximal end of tibia (1). There are a variety of treatments for a bone affected by GCT, ranging from chemotherapy, radiotherapy, embolization, and cryosurgery, to surgery with the use of chemical or...

متن کامل

Cementless Titanium Mesh Fixation of Osteoporotic Burst Fractures of the Lumbar Spine Leads to Bony Healing: Results of an Experimental Sheep Model

INTRODUCTION Current treatment strategies for osteoporotic vertebral compression fractures (VCFs) focus on cement-associated solutions. Complications associated with cement application are leakage, embolism, adjacent fractures, and compromise in bony healing. This study comprises a validated VCF model in osteoporotic sheep in order to (1) evaluate a new cementless fracture fixation technique us...

متن کامل

The Great Need of a Biomechanical-Based Approach for Surgical Methods of Giant Cell Tumor: A Critical Review

There are many unanswered questions about giant cell tumor (GCT) treatment and not enough attention is paid to the biomechanics of the current treatment methods. Treatment methods have not changed much, and the best method remains controversial to some degree, due to the lack of adequate clinical and biomechanical investigations. Biomechanical tests, including in vitro mechanical experiments co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014