Complication Rates Associated with Transvenous Pacemaker Implantation in Dogs with High‐Grade Atrioventricular Block Performed During versus After Normal Business Hours

نویسندگان

  • J.L. Ward
  • T.C. DeFrancesco
  • S.P. Tou
  • C.E. Atkins
  • E.H. Griffith
  • B.W. Keene
چکیده

BACKGROUND Transvenous pacemaker implantation in dogs is associated with a relatively high complication rate. At our institution, pacemaker implantation in dogs with high-grade atrioventricular block (HG-AVB) frequently is performed as an after-hours emergency. HYPOTHESIS Among dogs with HG-AVB, the rate of major complications is higher when pacemakers are implanted after hours (AH) compared to during business hours (BH). ANIMALS Client-owned dogs with HG-AVB that underwent transvenous pacemaker implantation between January 2002 and December 2012 at the North Carolina State University Veterinary Teaching Hospital. METHODS Retrospective medical record review. Two-year follow-up was required for complications analysis. RESULTS Major complications occurred in 14/79 dogs (18%) and included lead dislodgement, lead or generator infection, lead or generator migration, and pacing failure. Incidence of major complications was significantly higher AH (10/36, 28%) compared to BH (4/43, 9%; P = .041), and all infectious complications occurred AH. Median survival time for all dogs was 27 months and did not differ between AH and BH groups for either all-cause (P = .70) or cardiac (P = .40) mortality. AH dogs were younger than BH dogs (P = .010), but there were no other clinically relevant differences between BH and AH groups in terms of demographic, clinical, or procedural variables. CONCLUSIONS AND CLINICAL IMPORTANCE At our institution, AH transvenous pacemaker placement is associated with a higher rate of major complications (especially infections) compared to BH placement. This difference may be because of a variety of human factor differences AH versus BH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study.

Transcatheter aortic valve implantation is being established as an alternative treatment for some patients with symptomatic severe aortic stenosis who are not considered suitable for surgical aortic valve replacement because of prohibitive surgical risk.1–3 One of the potential complications is complete atrioventricular block requiring definitive pacemaker implantation. This complication occurs...

متن کامل

Asymptomatic Right Ventricular Perforation by a Temporary Transvenous Pacing Lead in an Infant.

UNLABELLED A 3-month-old male infant received transvenous temporary pacemaker for acquired complete atrioventricular block. However, a right ventricle perforation by the pacing lead was found incidentally when the patient was receiving permanent pacemaker implantation nineteen days after temporary pacing. There was no pacemaker dysfunction, active bleeding or hemopericardium. The temporary paci...

متن کامل

Early Complications and Malfunctions of Permanent Pacemaker Implantation: Single versus Dual-Chamber

BackgroundImplantation of transvenous permanent pacemakers (PPM) has become standard therapy for sinus node dysfunction and atrioventricular conduction abnormalities. It plays an important role in improving quality of life and preventing death in this group of patients. MethodsThis study was conducted on 477 patients during their hospitalization and eight weeks after their discharge. ResultsCom...

متن کامل

Permanently Implanted Transvenous

Three patients with complete heart block had a high resistance to electrical stimulation of the endocardium through transvenous pacemaker systems. One patient died; one needed reoperation for implantation of epicardial electrodes; and the third required a generator of higher current. The present enthusiasm for permanent transvenous implantation of pacemakers must be tempered somewhat by the kno...

متن کامل

Permanently Implanted Transvenous Pacemakers

Three patients with complete heart block had a high resistance to electrical stimulation of the endocardium through transvenous pacemaker systems. One patient died; one needed reoperation for implantation of epicardial electrodes; and the third required a generator of higher current. The present enthusiasm for permanent transvenous implantation of pacemakers must be tempered somewhat by the kno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015