Arterial Blood Flow Patterns in Human Subjects and Their Effect on Indicator Dilution Curves

نویسندگان

  • RAMON L. LANGE
  • CARLISLE SMITH
  • HANS H. HECHT
چکیده

Indicator dilution curves obtained from various systemic arterial sampling sites are commonly used for analysis of blood flow, cardiac shunts and valvular regurgitation, and for study of segments of the blood volume. It is generally assumed that the contour of such curves is largely determined by the passage and dilution of the indicator in the central circulation and that changes occurring during arterial passage are minor and predictable on the basis of the expected velocity of arterial blood flow and the distances of the commonly used sampling sites from the aortic root. Although it is accepted that quantification of blood flow is unaffected by changes in curve contour so long as the first circulation of indicator can be identified, the estimation of other parameters available from curve analysis may be significantly influenced by the validity of the above assumption. Beard, Wood and Clagett (1) and Fox, Sutterer and Wood (2) have demonstrated considerable differences in contour as well as appearance time of curves obtained from the femoral (FA), radial (RA) and dorsalis pedis arteries. The first study showed delay in the FA components in coarctation of the aorta as compared with the RA curve, whereas the latter study noted delay and skewing of the RA or pedal curve as compared with the FA curve. The FA curves were similar in contour to the abdominal aortic curves in normal subjects. During preliminary studies of an investigation which attempted to quantitate valvular regurgitation by comparison of indicator dilution curves recorded simultaneously from the pulmonary artery (PA) and a systemic artery, we noted that in normal subjects only FA curves consistently resembled the PA curve while those recorded from the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial blood flow patterns in human subjects and their effect on indicator dilution curves from various arterial sites.

Indicator dilution curves obtained from various systemic arterial sampling sites are commonly used for analysis of blood flow, cardiac shunts and valvular regurgitation, and for study of segments of the blood volume. It is generally assumed that the contour of such curves is largely determined by the passage and dilution of the indicator in the central circulation and that changes occurring dur...

متن کامل

Effect of coronary blood flow on radioiosotope dilution curves measured by precordial scintillation detection.

IN a comparison of radioactive bolus dilution curves obtained simultaneously by external monitoring' over the preeordium and by sampling from a peripheral artery, it was noted that arterial curves had a more rapid disappearance rate than precordial curves. This observation, made originally in human subjects, led to an investigation in animals designed to determine the reason for the distortion ...

متن کامل

A Simplified Method for Quantitating Left-to-Right Shunts from Arterial Dilution

This report presents a new, simple and reliable method of quantitating left-to-right shunts from arterial dilution curves. When indicator (e.g., indocyanine green) is injected centrally (right ventricle or pulmonary artery) and blood is withdrawn rapidly from either the aorta or other central systemic artery, in the presence of a left-to-right shunt the recorded indicator-dilution curve usually...

متن کامل

Abnormal Indicator Dilution Patterns in Dogs Produced by Flowmeter Probes on the Pulmonary Artery.

• Indicator dilution technics have been employed by Malooly and co-workers J for the in vivo calibration of electromagnetic flowmeter probes. In attempting to apply this calibration procedure to the measurement of pulmonary arterial flow in anesthetized dogs, we noted that the presence of the flowmeter probe on the pulmonary artery was frequently associated with abnormal indicator dilution curv...

متن کامل

Studies of coronary blood flow by multiple dye dilution curves.

The indicator-dilution technique has recently been applied to the study of the coronary circulation. One of the methods which have been proposed is the estimation of coronary blood flow from dilution curves sampled from the right ventricle after the injection of radio-iodinated human serum albumin into the left ventricle or into a catheter "wedged" in a branch of the pulmonary artery (1). Anoth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013