[Utility of the dead space fraction (Vd/Vt) as a predictor of extubation success].

نویسندگان

  • A González-Castro
  • V Suárez-Lopez
  • V Gómez-Marcos
  • C González-Fernandez
  • D Iglesias-Posadilla
  • J Burón-Mediavilla
  • J C Rodríguez-Borregan
  • E Miñambres
  • J Llorca
چکیده

PURPOSE To determine the value of Vd/Vt as a predictor of extubation failure in patients with mechanical ventilation admitted to the intensive care units. DESIGN A prospective, observational cohort study conducted from 1 September 2010 to 1 March 2011. SETTING General intensive care unit (G-ICU) of a third level university hospital. PATIENTS OR PARTICIPANTS The study included patients on mechanical ventilation (MV) for over 12 hours, and who in the process of weaning were subjected to low-level pressure support. Exclusion criteria were age under 18 years, ventilation via tracheotomy and patients failing to cooperate for different reasons. During the study, 392 patients were admitted to the G-ICU; of these, 214 required MV. The weaning process was started in 154 cases. Fifty-four patients were excluded from the study, and 24 were not extubated from MV. A total of 76 patients were finally extubated and analyzed. VARIABLES OF INTEREST Vd/Vt was calculated as the ratio (PaCO(2)-Pє CO(2))/PaCO(2), with the recorded parameters. RESULTS Logistic regression analysis showed a significant association between the Vd/Vt and extubation failure, with OR=1.52 (95%CI 1.11 to 2.09, p=0.008). The area under the ROC curve with respect to the prediction of extubation failure according to the Vd/Vt value was 0.94 (95%CI 0.86 to 0.98, p<0.0001). CONCLUSIONS Vd/Vt is a powerful predictor of extubation failure in patients on MV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the dead space to tidal volume ratio as a predictor of extubation failure.

OBJECTIVE The objective of this study was to evaluate the ratio of dead space to tidal volume (VD/VT) as a predictor of extubation failure of children from mechanical ventilation. METHODS From September 2001 to January 2003 we studied a cohort consisting of all children (1 day-15 years) submitted to mechanical ventilation at a pediatric intensive care unit who were extubated and for whom pre-...

متن کامل

Correction for mechanical dead space in the calculation of physiological dead space.

When physiological dead space (Vd(p)) is calculated for a patient who has alveolar dead space, e.g., after pulmonary vascular occlusion, less than the full volume of attached mechanical dead space (Vd(m)) appears in the measured dead space (Vd(n)). Under these conditions the traditional subtraction of Vd(m) from Vd(n) leads to underestimation of Vd(p) and can give a falsely small ratio of Vd(p)...

متن کامل

Predictive value of the physiological deadspace/tidal volume ratio in the weaning process of mechanical ventilation in children.

OBJECTIVE To evaluate the physiological deadspace/tidal volume ratio (VD/VT) as a predictor of extubation failure in 42 ventilated children (median age: 4.75 years). METHOD Extubation readiness was determined using the criteria proposed by the 6th International Consensus Conference on Intensive Care Medicine adapted to children. RESULTS Non-invasive ventilation (NIV) was used in four patien...

متن کامل

Bedside quantification of dead-space fraction using routine clinical data in patients with acute lung injury: secondary analysis of two prospective trials

INTRODUCTION Dead-space fraction (Vd/Vt) has been shown to be a powerful predictor of mortality in acute lung injury (ALI) patients. The measurement of Vd/Vt is based on the analysis of expired CO2 which is not a part of standard practice thus limiting widespread clinical application of this method. The objective of this study was to determine prognostic value of Vd/Vt estimated from routinely ...

متن کامل

Monitoring Dead Space in Mechanically Ventilated Children: Volumetric Capnography Versus Time-Based Capnography.

BACKGROUND Volumetric capnography dead-space measurements (physiologic dead-space-to-tidal-volume ratio [VD/VT] and alveolar VD/VT) are considered more accurate than the more readily available time-based capnography dead-space measurement (end-tidal alveolar dead-space fraction [AVDSF]). We sought to investigate the correlation between volumetric capnography and time-based capnography dead-spac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicina intensiva

دوره 35 9  شماره 

صفحات  -