A relationship between slide quality and image quality in whole slide imaging (WSI)

نویسندگان

  • Yukako Yagi
  • John R Gilbertson
چکیده

This study examined the effect of tissue section thickness and consistency--parameters outside the direct control of the imaging devices themselves--on WSI capture speed and image quality. Preliminary data indicates that thinner, more consistent tissue sectioning (such as those produced by automated tissue sectioning robots) results in significantly faster WSI capture times and better image quality. A variety of tissue types (including human breast, mouse embryo, mouse brain, etc.) were sectioned using an (AS-200) Automated Tissue Sectioning System (Kurabo Industries, Osaka Japan) at thicknesses from 2 - 9 microm (at one microm intervals) and stained with H&E by a standard method. The resulting slides were imaged with 5 different WSI devices (ScanScope CS, Aperio, CA; iScan, BioImagene, CA; DX40, DMetrix, AZ; NanoZoomer, Hamamatsu Photonics K.K., Japan; Mirax Scan, Carl Zeiss Inc., Germany) with sampling periods of 0.43 - 0.69 microm/pixel. Slides with different tissue thicknesses were compared for image quality, appropriate number of focus points, and overall scanning speed. Thinner sections (i.e. 3 microm sections versus 7 microm) required significantly fewer focus points and had significantly lower (10-15%) capture times. Improvement was seen with all devices and tissues tested. Furthermore, a panel of experienced pathologist judged image quality to be significantly better (for example, with better apparent resolution of nucleoli) with the thinner sections. Automated tissue sectioning is a very new technology; however, the AS-200 seems to be able to produce thinner, more consistent, flatter sections than manual methods at reasonably high throughput. The resulting tissue sections seem to be easier for a WSI system's focusing systems to deal with (compared to manually cut slides). Teaming an automated tissue-sectioning device with a WSI device shows promise in producing faster WSI throughput with better image quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of whole slide imaging in surgical pathology quality assurance: design and pilot validation studies.

By imaging large numbers of slides automatically at high resolution, modem automated whole slide imaging (WSI) systems have the potential to become useful tools in pathology practice. This article describes a pilot validation study for use of automated high-speed WSI systems for surgical pathology quality assurance (QA). This was a retrospective comparative study in which 24 full genitourinary ...

متن کامل

MGH Whole Slide Imaging Teleconsultation Practice in Dermatopathology

Nonsubspecialized pathologists frequently request expert consultation in challenging dermatopathology cases. Traditional consultation practice utilizing shipment of glass slides is costly, slow, and of limited educational benefit to the referring physician. Whole slide imaging (WSI) has been suggested as a potential method of overcoming these limitations in the current glass slide consultation ...

متن کامل

Primary histologic diagnosis using automated whole slide imaging: a validation study

BACKGROUND Only prototypes 5 years ago, high-speed, automated whole slide imaging (WSI) systems (also called digital slide systems, virtual microscopes or wide field imagers) are becoming increasingly capable and robust. Modern devices can capture a slide in 5 minutes at spatial sampling periods of less than 0.5 micron/pixel. The capacity to rapidly digitize large numbers of slides should event...

متن کامل

Validation of a Digital Pathology Whole Slide Imaging System

Digital whole slide imaging (WSI) provides a complement to traditional histopathology assessments of glass tissue slides for toxicologic pathology. WSI allows users to view images of entire slide content, or selected fields at increasing magnifications, and to compare multiple slide images simultaneously. The technology incorporates robust image databases with metadata and search & retrieval ca...

متن کامل

Validating whole slide imaging for diagnostic purposes in pathology: guideline from the College of American Pathologists Pathology and Laboratory Quality Center.

CONTEXT There is increasing interest in using whole slide imaging (WSI) for diagnostic purposes (primary and/or consultation). An important consideration is whether WSI can safely replace conventional light microscopy as the method by which pathologists review histologic sections, cytology slides, and/or hematology slides to render diagnoses. Validation of WSI is crucial to ensure that diagnost...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diagnostic Pathology

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2008