Dose Measurements in the Treatment of Mycosis Fungoides with Total Skin Irradiation using a 4 MeV Electron Beam
نویسندگان
چکیده
The total skin irradiation (TSI) is one of the most efficient techniques in the treatment administered with curative intent of the cutaneous T-cell lymphoma (mycosis fungoides). The cure may be obtained in 10% to 40% of the cases [13]. To irradiate all skin in an appropriate time of the machine, in most times, are used large electron fields with treatment distances about 3 meters. The original Stanford University technique [4], created in 1960, in which they irradiated the patient in all longitudinal extension, was applied in a 4.8 MeV linear accelerator, that provided 2.5 MeV electrons in the patient, by the use of 4 couple beams with the patient placed in front of the beam, 3 meters distant from the accelerator. In this work we describe a 4 MeV electron beam treatment method based on Stanford technique, where we used a Varian linear accelerator CLINAC 2100. We intend to improve the uniformity of the dose and to reduce the treatment time to the patient and also to reduce the problems with the overlapping treatment fields that occurs in conventional treatment that uses 1 meter of focus-skin distance. For this method the patient is placed on a rotative base and he assumes successively 6 positions: stand up and perpendicular to the beam, distant 2.83 meters from the source, with 60 degrees of interval between the rotations. In each position, the patient is irradiated by a couple of beams (the beam angulation is 19.5 degrees above the transversal axis in the middle of the patient and 19.5 degrees below it), figure 1a. A rotatory base makes easier the rotation of the patient, figure 1b.
منابع مشابه
Dosimetric characterization and optimization of a customized Stanford Total Skin Electron Irradiation (TSEI) technique
Total skin electron irradiation (TSEI) has been used as a treatment for mycosis fungoides. Our center has implemented a modified Stanford technique with six pairs of 6 MeV adjacent electron beams, incident perpendicularly on the patient who remains lying on a translational platform, at 200 cm from the source. The purpose of this study is to perform a dosimetric characterization of this techniqu...
متن کاملTotal skin electron therapy (TSET): Monte Carlo Simulation and implementation
Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...
متن کاملTotal Skin Electron Beam Therapy (TSEBT) in the Management of Mycosis Fungoides: Single Institution Experience
Purpose: To describe a protocol for total skin electron beam therapy (TSEBT) for the treatment of patients with mycosis fungoides (MF). We report the results of treatment and prognostic factors affecting the disease-free survival (DFS). Patients and methods: A total of 40 patients with the diagnosis of T1/T2 mycosis fungoides have been referred to the Department of Radiation Oncology at Nationa...
متن کاملA dosimetric study of deep skin electron therapy with overlapping stationary radiation fields – A case report
Background: For radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (Angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. The details of dosimetry, clinical dose measurements are presented. Materials and Methods: The treatment planned with 6 overlapping 9 MeV electron fields in ...
متن کاملTotal skin electron irradiation techniques: a review
Total skin electron irradiation (TSEI) has been employed as one of the methods of mycosis fungoides treatment since the mid-twentieth century. In order to improve the effects and limit the complications following radiotherapy, a number of varieties of the TSEI method, frequently differing in the implementation mode have been developed. The paper provides a systematic review of the different var...
متن کامل