A simple and selective sensor for the determination of ascorbic acid in vitamin C tablets based on paptode.

نویسندگان

  • Abdolkarim Abbaspour
  • Abdolreza Khajehzadeh
  • Abolhassan Noori
چکیده

A method for the determination of ascorbic acid in vitamin C tablets based on a very simple paptode design on TLC strips is described. This procedure is based on the reduction of iron(III) with ascorbic acid and the formation of a colorful red complex with immobilized 2,2'-dipyridyl (dipy) on TLC strips. The linear range of the system was 20-200 ppm with a detection limit of 1 ppm and a relative standard deviation of 1.5% (n = 28). The parameters, such as pH, concentration of iron(III), concentration of dipy and the volume of dipy per 1 cm(2) of TLC strips, were optimized. The proposed sensor was successfully applied for the determination of ascorbic acid in vitamin C tablets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Platinum Nanoparticle Electrode Modified Iodine using Cyclic Voltammetry and Chronoamperometry for Determination of Ascorbic Acid

This study investigated the oxidation of ascorbic acid (Vitamin C) using a platinum nanoparticle electrode coated with an iodine monolayer, called a modified electrode. The electrode were grown using the cyclic voltammetry technique and the electrochemical measurements were taken using the cyclic voltammetry and chronoamperometric technique. In the case of platinum nanoparticle electrode modifi...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

متن کامل

Indirect Determination of Ascorbic Acid by Atomic Absorption Spectroscopy

A new and simple method followed by atomic absorption spectrometry has been developedfor indirect determination of ascorbic acid (AA). The proposed method was based on the oxidationof AA to dehydroascorbic acid with Cu2+cation(200mgL-1)in an ammonium thiocyanatesolution atpH2.4. AA reduces Cu2+to Cu+followed by the precipitation of Cu+ with SCN-. Then, the excess ofCu2+in the solution was measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2008