BASIC SCIENCE INVESTIGATIONS Quantitative Gated PET for the Assessment of Left Ventricular Function in Small Animals
نویسندگان
چکیده
18F-FDG PET can identify areas of myocardial viability and necrosis and provide useful information on the effectiveness of experimental techniques designed to improve contractile function and myocardial vascularization in small animals. The left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) in normal and diseased rats were measured in vivo using the high-resolution avalanche photodiode (APD) small-animal PET scanner of the Université de Sherbrooke. The measurements obtained by PET were compared with those obtained by high-resolution echocardiography and with known values obtained from a small, variable-volume cardiac phantom. Methods: List-mode gated 18F-FDG PET studies were performed using the APD PET scanner on 30 rats: 11 healthy, 4 under septic shock, and 15 with heart failure induced by ligature of the left coronary artery. PET images were resized to match humanscale pixels and analyzed using a standard clinical cardiac software program. The LVV and LVEF from the same animals were also evaluated by echocardiography. Results: Agreement was excellent between the endocardial volumes determined by PET and the actual volumes of the cardiac phantom (r2 0.96). Agreement between PET and echocardiography for LVV ranged from good in healthy rats (r2 0.89) to fair in diseased rats (r2 0.49). Agreement was fair between LVEF values measured by the 2 methods (r2 0.56). Normal rats had an average LVEF of 83.2% 8.0% using PET and 81.6% 6.0% using echocardiography. In rats with heart failure, LVEF was 54.6% 15.9% using PET and 54.2% 13.3% using echocardiography. Conclusion: Both PET and echocardiography clearly differentiated normal rats from rats with heart failure. Echocardiography is fast and convenient, whereas list-mode PET is also able to assess defect size, myocardial viability, and metabolism.
منابع مشابه
Impact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI
Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...
متن کاملQuantitative gated PET for the assessment of left ventricular function in small animals.
UNLABELLED 18F-FDG PET can identify areas of myocardial viability and necrosis and provide useful information on the effectiveness of experimental techniques designed to improve contractile function and myocardial vascularization in small animals. The left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) in normal and diseased rats were measured in vivo using the high-reso...
متن کاملAssessment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emission tomography in patients with coronary artery disease.
BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کامل