Double Oscillating Diffusion Encoding (DODE) augments microscopic anisotropy contrast
نویسندگان
چکیده
Target audience. Researchers and clinicians interested in the brain’s microarchitecture and diffusion MR methods. Purpose. Generating a methodology capable of amplifying Double-Diffusion-Encoding MR’s sensitivity towards randomly oriented compartments. Introduction. Double Diffusion Encoding (DDE, Fig. 1A) [1] NMR and MRI techniques – more commonly known as Double Wave Vector (DWV) [2] or doublePulsed-Field-Gradient (dPFG) [3,4] – can resolve underlying microstructures of highly heterogeneous systems [3,4], which are prevalent in, e.g., Gray Matter (GM) tissues [2,3]. Angular DDE (Fig. 1B) provides its microstructural contrast in a model-free fashion by varying the relative orientation between G1 and G2 at long mixing time (tm), or, alternatively, by selecting wavevector schemes that deliver rotationally invariant metrics on the underlying compartment eccentricity [5,6]. At the heart of DDE experiments lies an amplitude modulation which represents the system’s microscopic anisotropy (μA). If the system is a-priori randomly oriented, DDE’s contrast can be quantified from the ratiometric signals at ψ=0° and ψ=90° [3,4]; a similar concept holds true for rotationally-invariant DDE schemes [5,6]. Here, we present a novel class of sequences, termed Double-Oscillating-DiffusionEncoding (DODE, Fig. 1C), which consist of two successive oscillating gradient encodings. Just as Oscillating-Gradient Spin-Echo (OGSE) modifications could augment size sensitivity in Single-Diffusion-Encoding (SDE) MR [7], we posit that DODE could enhance the sensitivity of DDE-like experiments. Methods. All simulations were performed using the MISST framework [8-10] and carried out on a conventional laptop computer equipped with an Intel i5 processor and 8GB of RAM. Each curve was generated within less than 5 minutes. The model involved finite length, randomly oriented cylinders, with lengths of L=10 μm and radii of R=1 or 2 μm, and a diffusion coefficient of 1E-9 m/sec. Signals were confined to the intra-cylindrical space. DDE experiments are typically sought in the short diffusion gradient regime, and long diffusion separation regime [4]; our simulations were therefore carried out using δ1=δ2=1ms, Δ1=Δ2=tm=50ms. The DODE sequence (Fig. 1C) was simulated with δ1=δ2=50ms and tm=50ms (tm is somewhat loosely defined in this sequence due to the multiple preceding gradient lobes), and the number of oscillations N was varied. For all simulations, |G1|=|G2|=40 G/cm. Results and Discussion. Figure 2A shows simulations of DDE and of corresponding DODE experiments with varying numbers of oscillations for L/d = 10/2 and 10/4, respectively. Conventional DDE experiment–under these experimental conditions–will not convey the underlying compartment eccentricity for either system; indeed, Figures 2C and 2D, showing normalized signals, reveal that DDE’s modulation is less than 1%. By contrast, DODE signals clearly convey the underlying microstructure via strong amplitude modulations. Very interestingly, the different scenarios seem to be contrast differently with N; for example, the N=4 sequence seems to be able to resolve the two scenarios, with ψ(π/2)/ψ(0) = 0.72 and 0.64, respectively, while, the N=1 DODE sequence (which in fact is a DDE sequence with very long gradient durations), yields ψ(π/2)/ψ(0) = ~0.2 for both scenarios. These results suggest a competition between signal attenuation due to accumulating diffusion weighting (e.g., increasing effective q-values), diffusion during gradient pulses (which, due to probing the boundaries whilst encoding diffusion, tend to reduce attenuation and thereby report on smaller apparent compartment sizes), and signal decay due to the parallel components of the signal (n.b. L/R>1). Much like SDE counterparts, such DDE sequences could be subject to optimization schemes [7] that would selectively probe subsets of randomly oriented cellular structures (e.g., neurites & astrocytic processes) classified by their microscopic anisotropy. It is worth noting that DODE’s signal enhancements can serve to (i) alleviate gradient-related constraints (including weak gradients and eddy currents); and (ii) provide better contrast to noise, allowing for reduced scanning time. Indeed, Finsterbusch [11] has proposed to successively concatenate multiple (short tm) DDE blocks in the long diffusion time regime, and has shown that this affords significant signal enhancements. The DODE sequences shown herein could avoid prohibitively long echo times involved in concatenating numerous DDE sequences, or the use of signal-consuming stimulated echoes. Furthermore, we note that the MISST framework can be used not only to generate DODE signals, but also to fit DODE data, as the entire time sequence of gradients played out are taken into account. This provides a simple means of analyzing such experiments even prior to the generation of rigorous analytical expressions. Finally, implementing such sequences in clinical and preclinical scanners should not pose a great challenge, as most scanners can already perform oscillating gradient experiments (which are normally “paired”, i.e., contain two gradient blocks); the only required modification is the manipulation of the second gradient’s orientation (Fig. 1C); the enhancement of DDE’s amplitude modulations offered by DODE sequences could indeed open up new possibilities for characterizing μA and underlying gray matter microstructures in clinical settings, where gradient amplitudes are generally limited to <6 G/cm. Conclusions. DODE MR shows much potential for resolving micro-architectural features of the CNS, especially in the elusive gray matter. References. [1] Mitra PP, Phys. Rev. B, 51 (1995) 15074-8. [2] Koch MA and Finsterbusch J, Magn. Reson. Med. 60 (2008) 90-101. [3] Shemesh N and Cohen Y, Magn. Reson. Med. 68 (2012) 794-806. [4] Özarslan E, J. Magn. Reson. 199 (2009) 56-67. [5] Lawrez M et al., J. Magn. Reson. 202 (2010) 43-56. [6] Jespersen SN et al, NMR Biomed. 26 (2013) 1647-62. [7] Drobnjak et al., J. Magn. Reson. 206 (2010) 41-51. I. [8] Drobnjak I, et al, J. Magn. Reson. 210 (2011) 151-7 [9] Ianus I et al. J. Magn. Reson. 227 (2013) 25-34 [10] Panagiotaki E, NeuroImage, 59:2241{2254, 2012. [11] Finsterbusch J, J. Magn. Reson. 198 (2009) 174-82. Figure 1. DDE and DODE sequences. (A) Conventional DDE sequence. (B) Angular DDE provides insights into μA in heterogeneous systems; (C) DODE sequences, comprising two oscillating gradient vectors having N oscillations each and separated by a mixing time.
منابع مشابه
Double oscillating diffusion encoding and sensitivity to microscopic anisotropy
PURPOSE To introduce a novel diffusion pulse sequence, namely double oscillating diffusion encoding (DODE), and to investigate whether it adds sensitivity to microscopic diffusion anisotropy (µA) compared to the well-established double diffusion encoding (DDE) methodology. METHODS We simulate measurements from DODE and DDE sequences for different types of microstructures exhibiting restricted...
متن کاملNeurite density imaging versus imaging of microscopic anisotropy in diffusion MRI: A model comparison using spherical tensor encoding
In diffusion MRI (dMRI), microscopic diffusion anisotropy can be obscured by orientation dispersion. Separation of these properties is of high importance, since it could allow dMRI to non-invasively probe elongated structures such as neurites (axons and dendrites). However, conventional dMRI, based on single diffusion encoding (SDE), entangles microscopic anisotropy and orientation dispersion w...
متن کاملObservation of microscopic diffusion anisotropy in the spinal cord using double-pulsed gradient spin echo MRI.
A double-pulsed gradient spin echo (d-PGSE) filtered MRI sequence is proposed to detect microscopic diffusion anisotropy in heterogeneous specimen. The technique was developed, in particular, to characterize local microscopic anisotropy in specimens that are macroscopically isotropic, such as gray matter. In such samples, diffusion tensor MRI (DTI) produces an isotropic or nearly isotropic diff...
متن کاملConventions and nomenclature for double diffusion encoding NMR and MRI.
Stejskal and Tanner's ingenious pulsed field gradient design from 1965 has made diffusion NMR and MRI the mainstay of most studies seeking to resolve microstructural information in porous systems in general and biological systems in particular. Methods extending beyond Stejskal and Tanner's design, such as double diffusion encoding (DDE) NMR and MRI, may provide novel quantifiable metrics that ...
متن کاملDetection of microscopic anisotropy in gray matter and in a novel tissue phantom using double Pulsed Gradient Spin Echo MR.
A double Pulsed Gradient Spin Echo (d-PGSE) MR experiment was used to measure and assess the degree of local diffusion anisotropy in brain gray matter, and in a novel "gray matter" phantom that consists of randomly oriented tubes filled with water. In both samples, isotropic diffusion was observed at a macroscopic scale while anisotropic diffusion was observed at a microscopic scale, however, t...
متن کامل