Measurement of angle kappa with synoptophore and Orbscan II in a normal population.

نویسندگان

  • Hikmet Basmak
  • Afsun Sahin
  • Nilgun Yildirim
  • Thanos D Papakostas
  • A John Kanellopoulos
چکیده

PURPOSE To obtain normative values of angle kappa in a normal population by synoptophore and Orbscan II and to compare the reliability of these devices. METHODS Three hundred consecutive healthy individuals were enrolled in the study. A complete orthoptic and ophthalmologic examination was performed. Synoptophore and Orbscan II corneal topography were used to measure angle kappa. To evaluate the association of the angle kappa and refraction measures, individuals were further classified according to the degree of myopia and hyperopia. The spherical equivalent error measures were grouped into six categories: > or = -3.00 diopters (D); -2.75 to -1.50 D; -1.25 to -0.50 D; +0.50 to +1.25 D; +1.50 to +2.75 D; and > or = +3.00 D. Paired t test and Pearson's correlation test were used for statistical analysis. RESULTS The mean age of the individuals was 28.74 +/- 1.63 years (range: 20 to 40 years). The angle kappa values obtained by synoptophore and Orbscan II were normally distributed. In the myopic group, angle kappa values decreased significantly towards negative refractive errors. In contrast, a correlation existed between large positive angles and positive refractive errors in the hyperopic group. Angle kappa values obtained by Orbscan II were significantly higher in all groups when compared to synoptophore (P < .0001). A significant correlation was noted between synoptophore and Orbscan II measurements (r = 0.932, P < .0001). CONCLUSIONS A significant correlation exists between positive refractive errors and large positive angle kappa values. Refractive surgeons must take into account angle kappa, especially in hyperopic patients, to avoid complications related to decentration of the ablation zone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angle Kappa Measurements: Normal Values in Healthy Iranian Population Obtained With the Orbscan II

BACKGROUND The angle kappa is important in proper centration of corneal ablation in keratorefractive surgery. Orbscan II device is widely used preoperatively in photoablation surgeries and can be used to measure the angle kappa. OBJECTIVES This study aimed to determine the mean angle kappa and its intercepts in healthy young Iranian adults. PATIENTS AND METHODS In this cross-sectional study...

متن کامل

Measurement of Angle Kappa Using Ultrasound Biomicroscopy and Corneal Topography

PURPOSE To introduce a new convenient and accurate method to measure the angle kappa using ultrasound biomicroscopy (UBM) and corneal topography. METHODS Data from 42 eyes (13 males and 29 females) were analyzed in this study. The angle kappa was measured using Orbscan II and calculated with UBM and corneal topography. The angle kappa of the dominant eye was compared with measurements by Orbs...

متن کامل

Central and Peripheral Corneal Thickness Measurement in Normal and Keratoconic Eyes Using Three Corneal Pachymeters

PURPOSE To assess the agreement among ultrasonic pachymetry, the Galilei dual Scheimpflug analyzer, and Orbscan II for central and peripheral (Galilei vs. Orbscan) corneal thickness (CCT and PCT) measurement in normal and keratoconic eyes. METHODS In this prospective study, CCT and PCT were measured in 88 eyes of 88 refractive surgery candidates and 128 eyes of 69 keratoconic patients with ul...

متن کامل

Comparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals

Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...

متن کامل

Measurement of Central Corneal Thickness Using Ultrasound Pachymetry and Orbscan II in Normal Eyes

PURPOSE To compare ultrasound pachymetry and Orbscan II for measurement of central corneal thickness (CCT) in normal eyes. METHODS The current study was performed at Labbafinejad Medical Center (LMC), Tehran, Iran. Three hundred eyes from 150 healthy individuals referred for keratorefractive surgery were assessed first by Orbscan II and then by ultrasound pachymetry, and CCT values were recor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 2007