Current status of the infrastructure and characteristics of radiation oncology in Korea.

نویسنده

  • Seung Jae Huh
چکیده

BACKGROUND An analysis of radiotherapy infrastructure in Korea was performed in 2006 to collect data on treatment devices, the work force and new patients for future development plans. METHODS The survey included radiotherapy centers, their major equipment and personnel. The centers were categorized into four levels: level 0 (stand-alone teletherapy units); level 1 (teletherapy, brachytherapy, treatment planning system, and at least the part-time service of a medical physicist); level 2 (level 1 plus individual customized radiotherapy block and full-time medical physicist); and level 3 [level 2 plus intensity-modulated radiation therapy (IMRT), intra-operative radiation therapy or stereotactic radiotherapy]. RESULTS A total of 61 facilities delivered radiation therapy with 104 megavoltage devices, which included 96 linear accelerators, two cobalt 60 units, three Tomotherapy, two CyberKnife units and one proton accelerator. There were 28,789 new radiotherapy patients in 2004. Personnel included 132 radiation oncologists, 50 radiation oncology residents, 64 physicists, 130 nurses and 369 radiation therapy technologists. Thirty-two percent (20 facilities) used a CT-simulator, 66% (40) used a PET or PET-CT scanner, and 35% (22) had the capacity to implement IMRT. Centers were also divided into four levels: 41% were included in level 3, 31% in level 2, 25% in level 1 and 3% in level 0. CONCLUSIONS There is a shortage of human resources. The distribution of megavoltage units per million inhabitants over the country was inadequate; geographic disparities were noted. Furthermore, the necessity of quality assurance for recent high-technology radiation therapy is increasing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Importance of total radiation dose and overall treatment time in T1 early glottic cancer

Background: In this study, we retrospectively reviewed the treatment outcome of 63 patients with T1 early glottic cancer treated with RT alone to determine the treatment outcome and the prognostic factors affecting local control. Materials and Methods: All patients were treated by 6 MV photons with conventional bilateral fields up to a median dose of 66 Gy in 33 fractions. Results: The 5-year l...

متن کامل

Dose distribution evaluation of various dose calculation algorithms in inhomogeneous media

Background: Dose calculation algorithms play a very important role in predicting the explicit dose distribution. We evaluated the percent depth dose (PDD), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. Materials and Methods: The homogeneous and inhomogeneous virtual slab phantoms used in th...

متن کامل

Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients

Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...

متن کامل

Dosimetric accuracy of the Acuros XB and Anisotropic analytical algorithm near interface of the different density media for the small fields of a 6- MV flattening-filter-free beam

Background: This study was conducted to assess the accuracy of dose calculation near the air-phantom interface of a heterogeneous phantom for Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) algorithm of a           6-MV flattening-filter-free beam, compared with film measurements. Materials and Methods: A phantom included air gap was ...

متن کامل

Human 3-D tissue models in radiation biology: current status and future perspectives

In this review, we discuss the use of a variety of 3-D models (particularly 3-D skin, lung, breast and endothelial) in radiobiological research and highlight the differences in responses compared to 2-D culturing conditions (monolayers). We review the characteristics of existing 3-D models and aim to point out the substantial advantages 3-D cultures provide for modern radiobiology. In particula...

متن کامل

Changes in the gastric ghrelin concentration after whole-abdominal irradiation in rats: Is this related to the radiation-induced anorexia and weight loss?

Background: Ghrelin is a hormone related to food intake in rodents and humans, mainly produced in stomach. This study aimed to determine the effect of irradiation on ghrelin concentration in the gastric mucosa of rats. Materials and Methods : Twenty-five rats were exposed to 15 Gy of whole-abdominal irradiation. Gastric tissue samples were obtained 1, 3, 7, 30, and 90 days after irradiation. Fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of clinical oncology

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 2007