Speech intelligibility benefits of hearing AIDS at various input levels.

نویسندگان

  • Francis Kuk
  • Chi-Chuen Lau
  • Petri Korhonen
  • Bryan Crose
چکیده

BACKGROUND Although the benefits of hearing aids are generally recognized for soft- and conversational-level sounds, most studies have reported negative benefits (i.e., poorer aided than unaided performance) at high noise inputs. Advances in digital signal processing such as compression, noise reduction, and directional microphone could improve speech perception at high input levels. This could alter our view on the efficacy of hearing aids in loud, noisy situations. PURPOSE The current study compared the aided versus the unaided speech intelligibility performance of hearing-impaired (HI) listeners at various input levels (from 50-100 dB SPL) and signal-to-noise ratios (SNRs; quiet, +6, +3, and -3 dB) in order to document the benefits of modern hearing aids. In addition, subjective preference between aided and unaided sounds (speech and music) at various input levels was also compared. RESEARCH DESIGN The experiment used a factorial repeated-measures design. STUDY SAMPLE A total of 10 HI adults with symmetrical moderate to severe hearing losses served as test participants. In addition, speech intelligibility scores of five normal-hearing (NH) listeners were also measured for comparison. INTERVENTION Speech perception was studied at 50 and 65 dB SPL input levels in quiet and also in noise at levels of 65, 85, and 100 dB SPL with SNRs of +6, +3, and -3 dB. This was done for all participants (HI and NH). In addition, the HI participants compared subjective preference between the aided and unaided presentations of speech and music stimuli at 50, 65, 85, and 100 dB SPL in quiet. DATA COLLECTION AND ANALYSIS The data were analyzed with repeated-measures analysis of variance. RESULTS The results showed a decrease in aided benefits as input levels increased. However, even at the two highest input levels (i.e., 85 and 100 dB SPL), aided speech scores were still higher than the unaided speech scores. Furthermore, NH listeners and HI listeners in the aided condition showed stable speech-in-noise performance between 65 and 100 dB SPL input levels, except that the absolute performance of the NH listeners was higher than that of the HI listeners. Subjective preference for the unaided sounds versus the aided sounds increased as input level increased, with a crossover intensity at approximately 75 dB SPL for speech and 80 dB SPL for music. CONCLUSIONS The results supported the hypothesis that the study hearing aid can provide aided speech-in-noise benefit at very high noise inputs in a controlled environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه وضوح گفتار کودکان کاشت حلزون شده، دارای سمعک و کودکان با شنوایی هنجار

Objective: The purpose of the present research was to compare speech intelligibility in children with cochlear implant, with hearing aids and normal hearing in Tehran province.  Materials & Methods: Sixty children underwent this analytic and comparative research. They were divided into three groups and each group contains 20 children. First and second group were selected, ordinarily, from ch...

متن کامل

Auditory Perception and Verbal Intelligibility in Children with Cochlear Implant, Hearing Aids and Normal Hearing

Objective: The aim of the present research was to compare the auditory perception and verbal intelligibility in children with cochlear implant, hearing aids and normal hearing. Methods: 60 children aged 5-7 years were divided to three groups and each group contained 20 children. The first and second groups were selected ordinarily from children with cochlear implant and hearing aids by conve...

متن کامل

A comparison of NAL and DSL prescriptive methods for paediatric hearing-aid fitting: predicted speech intelligibility and loudness.

OBJECTIVE To examine the impact of prescription on predicted speech intelligibility and loudness for children. DESIGN A between-group comparison of speech intelligibility index (SII) and loudness, based on hearing aids fitted according to NAL-NL1, DSL v4.1, or DSL m[i/o] prescriptions. A within-group comparison of gains prescribed by DSL m[i/o] and NAL-NL2 for children in terms of SII and lou...

متن کامل

Speech Intelligibility of Cochlear-Implanted and Normal-Hearing Children

Introduction: Speech intelligibility, the ability to be understood verbally by listeners, is the gold standard for assessing the effectiveness of cochlear implantation. Thus, the goal of this study was to compare the speech intelligibility between normal-hearing and cochlear-implanted children using the Persian intelligibility test.   Materials and Methods: Twenty-six cochlear-implanted childre...

متن کامل

NAL-NL1 procedure for fitting nonlinear hearing aids: characteristics and comparisons with other procedures.

A new procedure for fitting nonlinear hearing aids (National Acoustic Laboratories' nonlinear fitting procedure, version 1 [NAL-NL1]) is described. The rationale is to maximize speech intelligibility while constraining loudness to be normal or less. Speech intelligibility is predicted by the Speech Intelligibility Index (SII), which has been modified to account for the reduction in performance ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2015