Evaluation of an automated radioimmunoassay for serum cortisol.
نویسندگان
چکیده
The performance characteristics are reported for a serum cortisol assay using the GAMMAFLO Automated Assay System, an automated continuous-flow system for radioimmunoassay (RIA). This automated system utilizes a combination of continuous-flow methodology and column chromatography techniques. The cortisol assay studied had a standard curve range of 10.0 to 500 microgram per L. The intra-assay and inter-assay precision were 5.1 percent and 7.2 percent (RSD), respectively, for a cortisol concentration of 160 microgram per L. The automated serum cortisol results correlated (r = 0.958 and 0.933) with two established manual radioimmunoassay procedures. No drift or carryover was detectable in 200 within-assay consecutive determinations performed at a rate of 42 determinations per hour (five hours continuous operation). The automated system studied appears to offer a viable alternative to cortisol manual RIA techniques in terms of overall precision simplicity of operation, and sample throughput.
منابع مشابه
Performance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملComparison of VIDAS and Radioimmunoassay Methods for Measurement of Cortisol Concentration in Bovine Serum
Radioimmunoassay (RIA) is the "gold standard" method for evaluation of serum cortisol concentration. The VIDAS cortisol test is an enzyme-linked fluorescent assay designed for the MiniVidas system. The aim of this study was to compare the VIDAS method with RIA for measurement of bovine serum cortisol concentration. Cortisol concentrations were evaluated in 40 cows using both VIDAS and RIA metho...
متن کاملChanges of Cortisol and Glucose Concentrations in Rats Exposed to MR Imaging Field
Background: MR imaging is one of the best diagnostic modalities in medicine. During an MR imaging examination, three types of field are employed to produce images. Various experimental studies have been performed about the effects of each single type of field but only few studies are available on their combination to generate MR imaging. The main objective of this research work is to study the ...
متن کاملComparison of clinical assays for serum corticosteroids.
We compared results obtained by (a) chemical (spectrophotometric) and competitive protein-binding assays for serum corticosteroids, and (b) competitive protein-binding and radioimmunoassay, with and without CCI-4 extraction, for serum cortisol. The two corticosteroid methods gave identical results. Radioimmunoassay with and without a CCI-4 extraction step gave identical results for cortisol. Co...
متن کاملA simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.
A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and an 125I radioligand in a low-pH buffer, which denatures cortisol-binding globul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 10 6 شماره
صفحات -
تاریخ انتشار 1980