IMRT using simultaneously integrated boost (SIB) in head and neck cancer patients

نویسندگان

  • G Studer
  • PU Huguenin
  • JB Davis
  • G Kunz
  • UM Lütolf
  • C Glanzmann
چکیده

BACKGROUND Preliminary very encouraging clinical results of intensity modulated radiation therapy (IMRT) in Head Neck Cancer (HNC) are available from several large centers. Tumor control rates seem to be kept at least at the level of conventional three-dimensional radiation therapy; the benefit of normal tissue preservation with IMRT is proven for salivary function. There is still only limited experience with IMRT using simultaneously integrated boost (SIB-IMRT) in the head and neck region in terms of normal tissue response.The aim of this work was (1) to establish tumor response in HNC patients treated with SIB-IMRT, and (2) to assess tissue tolerance following different SIB-IMRT schedules. RESULTS Between 1/2002 and 12/2004, 115 HNC patients have been curatively treated with IMRT. 70% received definitive IMRT (dIMRT), 30% were postoperatively irradiated. In 78% concomitant chemotherapy was given. SIB radiation schedules with 5-6 x 2 Gy/week to 60-70 Gy, 5 x 2.2 Gy/week to 66-68.2 Gy (according to the RTOG protocol H-0022), or 5 x 2.11 Gy/week to 69.6 Gy were used. After mean 18 months (10-44), 77% of patients were alive with no disease. Actuarial 2-year local, nodal, and distant disease free survival was 77%, 87%, and 78%, respectively. 10% were alive with disease, 10% died of disease. 20/21 locoregional failures occurred inside the high dose area. Mean tumor volume was significantly larger in locally failed (63 cc) vs controlled tumors (32 cc, p <0.01), and in definitive (43 cc) vs postoperative IMRT (25 cc, p <0.05); the locoregional failure rate was twofold higher in definitively irradiated patients. Acute reactions were mild to moderate and limited to the boost area, the persisting grade 3/4 late toxicity rate was low with 6%. The two grade 4 reactions (dysphagia, laryngeal fibrosis) were observed following the SIB schedule with 2.2 Gy per session. CONCLUSION SIB-IMRT in HNC using 2.0, 2.11 or 2.2 Gy per session is highly effective and safe with respect to tumor response and tolerance. SIB with 2.2 Gy is not recommended for large tumors involving laryngeal structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary analysis of the sequential simultaneous integrated boost technique for intensity-modulated radiotherapy for head and neck cancers

The aim of this study was to compare three strategies for intensity-modulated radiotherapy (IMRT) for 20 head-and-neck cancer patients. For simultaneous integrated boost (SIB), doses were 66 and 54 Gy in 30 fractions for PTVboost and PTVelective, respectively. Two-phase IMRT delivered 50 Gy in 25 fractions to PTVelective in the First Plan, and 20 Gy in 10 fractions to PTVboost in the Second Pla...

متن کامل

Simultaneous integrated boost-intensity-modulated radiotherapy in head and neck cancer.

OBJECTIVES/HYPOTHESIS To review toxicity and outcomes in patients with head and neck cancer treated with simultaneous integrated boost-intensity-modulated radiotherapy (SIB-IMRT). STUDY DESIGN Review of experience with the SIB-IMRT technique. METHODS Fifty patients were treated with the SIB-IMRT technique. Two possible schedules of radiation therapy (RT) were used: SIB 70 (70/60/54 in 33 fr...

متن کامل

Comparison of 3D Confromal Radiotherapy and Intensity Modulated Radiotherapy with or without Simultaneous Integrated Boost during Concurrent Chemoradiation for Locally Advanced Head and Neck Cancers

OBJECTIVE Radiotherapy techniques have evolved from 3D conformal radiotherapy (3D-CRT) to intensity modulated radiotherapy (IMRT) where boost fields are delivered either sequentially (IMRTseq) or with a simultaneous integrated boost (IMRT+SIB). Our goal was to compare the outcomes of patients treated with IMRT+SIB to traditional standards. METHODS We analyzed the efficacy and toxicity of pati...

متن کامل

SU-E-T-595: A Study of Sequential and Simultaneously Integrated Boost IMRT Methods in Head and Neck Cancer.

PURPOSE The purpose of this study was to obtain the characteristics of the sequential (SqB) and simultaneous integrated boost (SIB) IMRT methods in head and neck cancer using HART (Histogram Analysis in Radiation Therapy) program. METHODS Ten SqB and seventeen SIB IMRT cases were studied retrospectively. A cumulative mean dose of 71.3 Gy was prescribed sequentially, and a mean dose of 66.2 Gy...

متن کامل

Simultaneously integrated boost (SIB) spares OAR and reduces treatment time in locally advanced cervical cancer

We performed a dosimetric comparison of sequential IMRT (sIMRT) and simul-taneously integrated boost (SIB) IMRT to boost PET-avid lymph nodes while concurrently treating pelvic targets to determine the potential of SIB IMRT to reduce overall treatment duration in locally advanced cervical cancer. Ten patients receiving definitive radiation therapy were identified retrospectively. RTOG consensus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation Oncology (London, England)

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2006