Aerosol delivery of recombinant human DNase I: in vitro comparison of a vibrating-mesh nebulizer with a jet nebulizer.

نویسندگان

  • Jeremy C Johnson
  • J Clifford Waldrep
  • Jennifer Guo
  • Rajiv Dhand
چکیده

BACKGROUND Inhaled recombinant human DNase I (rhDNase) improves clearance of visco-elastic secretions in patients with cystic fibrosis. Because of their portability, newer-generation vibrating-mesh nebulizers offer greater convenience for the patient, but their efficiency in delivering rhDNase has not been determined. METHODS We compared a newer-generation vibrating-mesh nebulizer (Omron MicroAir) to a Pari LC+ with the Pari ProNeb Ultra compressor (a commonly employed rhDNase administration system). With the Next Generation Pharmaceutical Impactor, we determined aerosol particle distribution. We also measured mass output efficiency, nebulization time, and mass of rhDNase that deposited on a filter during simulated breathing. RESULTS The mass median aerodynamic diameter (MMAD) and geometric standard deviation (GSD) of aerosol from the MicroAir (MMAD 4.3 microm, GSD 2.8 microm) was equivalent to that from the Pari LC+ (MMAD 4.2 microm, GSD 2.7 microm). During simulated breathing the MicroAir had a higher total mass output efficiency (88%) than the Pari LC+ (68%) (P < .001), and total nebulization time was shorter with the MicroAir (6.1 min vs 7.2 min, P = .03). When nebulized to dryness, the mass of rhDNase delivered to the filter was comparable with the MicroAir (1.30 +/- 0.4 mg) and Pari LC+ (1.21 +/- 0.05 mg). CONCLUSION The MicroAir could be employed as a portable nebulizer for rhDNase therapy in patients with cystic fibrosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.

BACKGROUND The effectiveness of aerosol drug delivery during mechanical ventilation is influenced by the patient, ventilator, and nebulizer variables. The impact of nebulizer type, position on the ventilator circuit, and bias flow on aerosol drug delivery has not been established for different age populations. OBJECTIVE To determine the influence of nebulizer position and bias flow with a jet...

متن کامل

Transnasal Aerosol Delivery to Pediatric Patients: Jet Versus Vibrating Mesh--Reply.

To the Editor: In the recent paper by El Taoum and associates,1 an in vitro comparison of aerosol dose delivery using jet and vibrating mesh nebulizers with a variety of nasal interface devices in pediatric patient models was presented. The results of this study demonstrated that the jet nebulizer was more efficient than the vibrating mesh nebulizer across all of the nasal interface devices tes...

متن کامل

Effect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Tracheostomy Model.

BACKGROUND This study was conducted to compare the efficiency of jet nebulizers, vibrating mesh nebulizers, and pressurized metered-dose inhalers (pMDI) during assisted and unassisted administration techniques using a simulated spontaneously breathing pediatric model with a tracheostomy tube (TT). METHODS An in vitro breathing model consisting of an uncuffed TT (4.5-mm inner diameter) was att...

متن کامل

Albuterol delivery in an in vitro pediatric ventilator lung model: comparison of jet, ultrasonic, and mesh nebulizers.

OBJECTIVE To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN In vitro, laboratory study. SETTING Research laboratory of a university hospital. INTERVENTIONS Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 53 12  شماره 

صفحات  -

تاریخ انتشار 2008