The Critical Role of Channel Cross-Sectional Area in Microchannel Flow Boiling Heat Transfer

نویسندگان

  • Tannaz Harirchian
  • S V. Garimella
  • Suresh V. Garimella
چکیده

Experiments are conducted with a perfluorinated dielectric fluid, Fluorinert FC-77, to identify the critical geometric parameters that affect flow boiling heat transfer and flow patterns in microchannels. In recent work by the authors (Harirchian and Garimella IJMF 35:349-362, 2009), seven different silicon test pieces containing parallel microchannels of widths ranging from 100 μm to 5850 μm, all with a depth of 400 μm were tested and it was shown that for a fixed channel depth, the heat transfer coefficient was independent of channel width for microchannels of widths 400 μm and larger, with the flow regimes in these microchannels being similar; nucleate boiling was also found to be dominant over a wide range of heat fluxes. In the present study, experiments are performed with five additional microchannel test pieces with channel depths of 100 μm and 250 μm and widths ranging from 100 μm to 1000 μm. Flow visualizations are performed using a high-speed digital video camera to determine the flow regimes, with simultaneous local measurements of the heat transfer coefficient and pressure drop. The aim of the present study is to investigate as independent parameters the channel width and depth as well as the aspect ratio and cross-sectional area on boiling heat transfer in microchannels, based on an expanded database of experimental results. The flow visualizations and heat transfer results show that the channel cross-sectional area is the important governing parameter determining boiling mechanisms and heat transfer in microchannels. For channels with cross-sectional area exceeding a specific value, nucleate boiling is the dominant mechanism and the boiling heat transfer coefficient is independent of channel dimensions; below this threshold value of cross-sectional area, vapor confinement is observed in all channels at all heat fluxes, and the heat transfer rate increases as the microchannel cross-sectional area decreases before premature dryout occurs due to channel confinement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comprehensive flow regime map for microchannel flow boiling with quantitative transition criteria

Due to the critical role of vapor confinement in establishing distinct flow and heat transfer characteristics in microchannels (as distinct from those in larger channels), the conditions under which such confinement occurs in microchannels are of great interest. It is shown in the present work that channel dimensions and flow properties alone, as proposed in past studies, are insufficient for d...

متن کامل

A Systematic Investigation of the Effects of Microchannel Width, Depth, and Aspect Ratio on Convective Boiling Heat Transfer and Flow Regimes in Parallel Microchannels

Experiments are conducted with a perfluorinated dielectric fluid, Fluorinert FC-77, to investigate the effects of channel width, depth, and aspect ratio on flow boiling heat transfer and flow patterns in microchannels. Experiments are performed for a fixed mass flux of 630 kg/ms with eleven different silicon test pieces containing parallel microchannels of widths ranging from 100 μm to 5850 μm ...

متن کامل

Microchannel size effects on local flow boiling heat transfer to a dielectric fluid

Heat transfer with liquid–vapor phase change in microchannels can support very high heat fluxes for use in applications such as the thermal management of high-performance electronics. However, the effects of channel cross-sectional dimensions on the two-phase heat transfer coefficient and pressure drop have not been investigated extensively. In the present work, experiments are conducted to inv...

متن کامل

Experimental study of convective heat transfer coefficient of MgO nanofluid in a cylindrical microchannel heat sink

Convective heat transfer of MgO-water nanofluid in a microchannel heat sink is experimentally investigated in various concentrations of 0.01, 0.05, 0.1, and 0.6 wt%. The microchannel consisted of 48 parallel rectangular cross section channels with the height of 800 µm, width of 524 µm and length of 52 mm. A well stability duration (ca. 1 month) was resulted by a 180 min ultra-sonication of the ...

متن کامل

Experimental Study on Saturated Flow Boiling Critical Heat Flux in Microchannels

The saturated flow boiling critical heat flux in microchannels is investigated using water as the working fluid. The experimental test section has six parallel microchannels with each having a cross sectional area of 1054 × 157 micrometers. The mass flow rate, inlet temperature of the working fluids, and the electric current supplied to the resistive cartridge heater are controlled to provide q...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015