The Abbott IMx automated benchtop immunochemistry analyzer system.

نویسندگان

  • M Fiore
  • J Mitchell
  • T Doan
  • R Nelson
  • G Winter
  • C Grandone
  • K Zeng
  • R Haraden
  • J Smith
  • K Harris
چکیده

We describe a new clinical laboratory instrument, the IMx, used to automate immunoassay testing in the clinical laboratory. The IMx incorporates a novel technology called Microparticle capture Enzyme ImmunoAssay (MEIA) for assays of high-molecular-mass analytes, and fluorescence polarization immunoassay (FPIA) for hapten assays. A front-surface fluorometer is used to quantify the enzymatic generation of fluorescent product at a rate proportional to the concentration of the analyte in an MEIA, and a fluorescence polarization optical system is used to quantify results in an FPIA. The microprocessor-based instrument uses a robotic arm with two degrees of freedom and a rotating carousel to process the samples for assay. One assay can be done on each of 24 patients' specimens in 30 to 40 min with "walk-away" automation. Calibration curves are stable for at least two weeks. Instrument control involves software-labeled "command keys," a numeric keypad, and an interactive display. Results are output to a thermal printer or computer interface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated enzyme immunoassay for lutropin with the Abbott IMx analyzer.

An automated enzyme immunoassay for human lutropin for use with the Abbott IMx analyzer is described. The assay provides results in approximately 40 min with a sensitivity of 0.25 int. units of LH per liter for up to 23 serum or plasma samples. Cross-reactivity with follitropin (2000 int. units/L) and thyrotropin (2 int. units/L) was negligible; it was 0.016% with human choriogonadotropin (1 X ...

متن کامل

Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.

We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuring the quenching by heme of the static fluorescence from an added fluorophore....

متن کامل

Three assays for glycohemoglobin compared.

Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an HPLC method measuring HbA1c by cation-exchange chromatography on a PolyCAT A ...

متن کامل

Glycogen phosphorylase BB and other cardiac proteins: challenges to creatine kinase MB as the marker for detecting myocardial injury.

Rapid, Fully Automated Measurement of Plasma Homocyst(e)ine with the Abbott IMx#{174} Analyzer. Mohammed T. Shipchandler, Edwin G. Moore 991 Candidate Reference Method for Determining Serum Creatimne by Isocratic HPLC: Validation with Isotope Dilution Gas Chromatography-Mass Spectrometry and Application for Accuracy Assessment of Routine Test Kits. Linda M. Thienpont, Katrien G. Van Landuyt, Di...

متن کامل

Comparison of Five Methods for the Determination of Rubella Immunity

OBJECTIVE The purpose of this study was to compare the accuracy of commonly used methods for the detection of rubella immunity, especially the fully automated IMx assay. METHODS A total of 190 sera (101 immune and 89 non-immune) submitted to Harrisburg Hospital or Polyclinic Medical Center for the determination of rubella immunity were tested by enzyme immunoassay (IMx and Rubazyme, Abbott Di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 9  شماره 

صفحات  -

تاریخ انتشار 1988