Schirmer test changes after 20 gauge and 23 gauge pars plana vitrectomy
نویسندگان
چکیده
Objective: To evaluate the short-term changes in Schirmer I test (ST) after pars plana vitrectomy and to compare the results between 23 gauge and 20 gauge vitrectomy surgeries. Methods: 42 patients who underwent pars plana vitrectomy for posterior segment diseases were included in this prospective, non-randomized, comparative study. The choice of sclerotomy gauge was at the surgeons' discretion. ST values were recorded before and at 1 and 3 months after vitrectomy. Results: 20 patients in 23 gauge and 22 patients in 20-gauge group with a mean age of 59.9 ± 13.5 years were included. The mean preoperative ST values decreased significantly in both groups at 1 and 3 months after surgery (all P < 0.01). The ST values in the fellow eyes were the same, at baseline and during the follow up (P > 0.05). At 3 months visit, 15 eyes (35.7%) had abnormal ST measurements. There was no statistically significant difference in the changes in the ST measurements between the two groups at one month (P = 0.7), however, 3 months after surgery, the mean decrease in the ST measurements was significantly higher in the 20 gauge group (P = 0.03). At 3 months, 4 eyes in the 23 gauge group (20%) and 11 eyes in the 20 gauge group (50%) had abnormal ST measurements (P = 0.05). Conclusions: Although both 20 and 23-gauge vitrectomy decrease the ST measurements postoperatively, the value is less affected by the 23-gauge vitrectomy.
منابع مشابه
Advances in Vitreo-retinal Surgery: 23-gauge Sutureless Pars Plana Vitrectomy
Pars plana vitrectomy is one of the most common surgical procedures performed for the treatment of various vitreo-retinal diseases such as retinal detachment, vitreous haemorrhage, proliferative diabetic retinopathy, epiretinal membrane and macular hole. Traditionally, most vitrectomy surgical systems utilise the 20-gauge instruments pars plana vitrectomy includes multiple incisions including p...
متن کاملOcular surface molecule after transconjunctival vitrectomy.
AIM To evaluate ocular surface molecules after transconjunctival pars plana vitrectomy (PPV). METHODS A total of 28 eyes of 28 patients who received PPV were examined. Tears (10μl) were collected before and after 20-gauge PPV or 23-gauge PPV. The concentrations of interleukin (IL)-1β, IL-6, IL-8, IL-10, IL-12p70 and tumour necrosis factor (TNF)-α were measured. The concentrations of each cyto...
متن کاملChanges in Day 1 Post-Operative Intraocular Pressure Following Sutureless 23-Gauge and Conventional 20-Gauge Pars Plana Vitrectomy
BACKGROUND/AIMS The benefits associated with transconjunctival sutureless vitrectomy techniques are continuing to be defined. The purpose of this study was to compare the incidence of extreme changes in day 1 intraocular pressure (IOP) following 23-gauge sutureless vitrectomy compared with conventional 20-gauge vitrectomy. METHODS Fifty consecutive 23-gauge and 50 consecutive 20-gauge cases w...
متن کاملIncidence of endophthalmitis after 20- and 25-gauge vitrectomy.
PURPOSE To assess the incidence rate of endophthalmitis after 25-gauge pars plana vitrectomy and to compare it with the endophthalmitis rate after 20-gauge pars plana vitrectomy. DESIGN Retrospective, interventional, comparative cohort study. PARTICIPANTS Eight thousand six hundred one consecutive pars plana vitrectomy surgery patients. METHODS Surgeries performed at a single institution ...
متن کاملComparison of 23 gauge and 25 gauge PPV in the treatment of epiretinal membranes and macular holes.
The aim of this study was to show the long term recovery after the operative procedure of pars plana vitrectomy (PPV) in patients with epiretinal membranes (ERM) and macular holes. We wanted to show if there is a difference in operative approach and results of 23 and 25 gauge PPV Twenty eight patients underwent to operative treatment of idiopatic ERM and macular holes grade III and IV In our st...
متن کامل