Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?

نویسندگان

  • Aristomenis Manouras
  • Kambiz Shahgaldi
  • Reidar Winter
  • Lars-Åke Brodin
  • Jacek Nowak
چکیده

BACKGROUND Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis. METHODS In this study, left ventricular longitudinal systolic displacement was quantified in 57 patients (31 women and 26 men, 50 +/- 16 years) using colour (colour TD) and spectral tissue Doppler (spectral TD) before and after temporal filtering (30 to 70 milliseconds in 20-millisecond steps) and changed offline gain saturation (0%, 50% and 100%), respectively. The results were compared with those obtained with anatomic M-mode. RESULTS Whereas only minor differences occurred between the results of colour TD and anatomic M-mode measurements, spectral TD significantly overestimated the results obtained with both these methods. However, the limits of agreement between the results produced by all three studied methods were not clinically acceptable in any of the cases. The spectral TD displacement values increased along with increasing offline gain saturation whereas the effect of temporal filtering on colour Doppler measurements was insignificant. CONCLUSION Measurements of LV myocardial longitudinal displacement employing spectral TD, colour TD or anatomic M-mode produce different results, thus discouraging interchangeable use of these modalities. Whereas the results of spectral TD measurements can be significantly altered by changing offline gain setting, the effect of temporal filtering on colour TD measurements is insignificant, a fact that increases clinical practicality of the latter method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?

BACKGROUND Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and diff...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

Echocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation

Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...

متن کامل

The Effect of Bronchial Asthma on Interatrial Electromechanical Delay Coupling Obtained Using Tissue Doppler Imaging

Background: Asthma is a predisposing factor for the development of atrial fibrillation. Asthma disturbs the electrophysiology in the right and left atrium. The aim of this study was to evaluate atrial electromechanical delay by coupling obtained from tissue Doppler imaging (TDI) in children. Methods: A cross-sectional study was conducted on 50 patients with Bronchial Asthma, compared with 50 hea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2009