Does Patient’s Initial Evaluation Predict a Change in Optimal Pressure on CPAP Retitration?
نویسنده
چکیده
Introduction: Only vindication of a nasal continuous positive airway pressure (CPAP) retitration procedure will be an actual change in the optimal CPAP pressure after that test. The purpose of this study was to identify any items in patient characteristics, clinical features, baseline PSG and initial CPAP titration as predictors of change in optimal pressure on CPAP retitration. Methods: 46 patients with obstructive sleep apnea (OSA) were divided in two groups: Group I (optimal pressure was changed on CPAP retitration): N = 30, M 22 and F 8, age 31 72, BMI 26 50 Kg/m, neck size 15 – 20", tonsillectomy in 8, narrow oropharynx in 15, uvuvlopalatopharyngoplasty (UP3) in 2, abnormal chin in 3, deviated nasal septum (DNS) and prior nose surgery in 1 each, initial CPAP pressure 6 19 cm, sleep efficiency 65% 98%, REM latency 0 304 minutes and residual apnea hypopnea index (AHI) 0 23/hour. Group II (optimal pressure unchanged after CPAP retitration): N = 16, M 11 and 5 F, age 32 69, BMI 23 62 Kg/m, neck size 14.5 20", tonsillectomy in 6, narrow oropharynx in 5, abnormal chin in 4, corrective nasal surgery in 2, DNS in 1, initial CPAP pressure 8 13 cm of H2O, sleep efficiency 69% 95%, REM latency 0 270 minutes and residual AHI 0 19/hour. The statistical analyses were performed using two-tailed Fisher’s t test and unpaired t test. A p value of <0.05 was considered statistically significant. Results: Patient characteristics (age, gender, neck size, and BMI), clinical features (tonsillar status, oropharyngeal narrowing, chin abnormality, DNS/nasal surgery or UP3), baseline PSG or initial CPAP titration (sleep efficiency, REM latency, residual AHI and initial CPAP pressure) did not differ significantly between the 2 groups (p = 0.09 0.99). Conclusion: Patient characteristics, clinical features or variables on baseline PSG and initial CPAP titration do not predict a change in optimal pressure on CPAP retitration. The results suggest that 1) Significant weight change; 2) Patient’s subjective feeling of pressure being too high or insufficient; 3) Residual or recurrent daytime sleepiness uncorrected by interface readjustments; 4) Post-operative evaluation after palliative UP3 Maxillomandibular advancement or tonsillectomy and adenoidectomy; and 5) Annual retitrations in high risk occupations (e.g. truck driver or pilot) are the best current, empiric and clinical guidelines for CPAP retitration.
منابع مشابه
Efficacy of automated continuous positive airway pressure in children with sleep-related breathing disorders in an attended setting.
INTRODUCTION The purpose of this study was to evaluate the safety and efficacy of automated continuous positive airway pressure (Auto-CPAP) in children. Sleep-related breathing disorders (SRBDs) include the clinical spectrum of symptomatic chronic snoring, upper airway resistance syndrome, and obstructive sleep apnea. This spectrum occurs in adults and children. Less data are available for chil...
متن کاملPrediction of optimal CPAP pressure and validation of an equation for Asian patients with obstructive sleep apnea.
BACKGROUND The Hoffstein formula is the most widely used equation to predict optimal CPAP pressure in patients with obstructive sleep apnea, but it is based on data from white patients. The purpose of this study was to develop an equation for optimal CPAP based on data from Asian patients, and to compare this new formula with the Hoffstein formula. METHODS We retrospectively reviewed the reco...
متن کاملInterventions to improve compliance in sleep apnea patients previously non-compliant with continuous positive airway pressure.
STUDY OBJECTIVES Despite widespread agreement that continuous positive airway pressure is effective therapy for obstructive sleep apnea, it is estimated that 50% of patients recommended for therapy are noncompliant 1 year later. Interventions to improve compliance in such patients have not been studied. We evaluated a 2 phase intervention program to improve compliance in sleep apnea patients pr...
متن کاملClinical predictors of effective continuous positive airway pressure in patients with obstructive sleep apnea/hypopnea syndrome.
OBJECTIVES/HYPOTHESIS To identify standard clinical parameters that may predict the optimal level of continuous positive airway pressure (CPAP) in adult patients with obstructive sleep apnea/hypopnea syndrome (OSAHS). STUDY DESIGN This is a retrospective study in a tertiary academic medical center that included 129 adult patients (117 males and 12 females) with OSAHS confirmed by diagnostic p...
متن کاملConcerns regarding the pediatric component of the AASM clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea.
Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBDs), including obstructive sleep apnea (OSA). After a patient is diagnosed with OSA, the current standard of practice involves performing attended polysomnography (PSG), during which positive airway pressure is adjusted throughout the recording period to determine the optimal pressure fo...
متن کامل