[Meconium-stained amniotic fluid and maternal and neonatal factors associated].

نویسندگان

  • Ruth Hitomi Osava
  • Flora Maria Barbosa da Silva
  • Sonia Maria Junqueira Vasconcellos de Oliveira
  • Esteban Fernandez Tuesta
  • Maria Clara Estanislau do Amaral
چکیده

OBJECTIVE To identify the frequency and maternal and neonatal factors associated with meconium-stained amniotic fluid at birth. METHODS Cross-sectional study carried out with 2,441 births at an in-hospital birth center in the city of São Paulo (Southeastern Brazil) in March and April, 2005. The association between meconium-stained amniotic fluid and the independent variables (maternal age, parity, previous c-section or not, gestational age, obstetric history, oxytocin use in the labor, cervical dilation at admission, mode of current delivery, newborn weight, Apgar score at the 1st and 5th minute) was expressed as prevalence ratio (PR). RESULTS Meconium-stained amniotic fluid was verified in 11.9% of the births; 68.2% of these were normal births and 38.8% c-sections. Meconium was associated with: primiparity (PR=1.49, 95%CI 1.29; 1.73), gestational age ≥ 41 weeks (PR = 5.05, 95%CI 1.93;13.25), oxytocin in labor (PR = 1.83, 95%CI 1.60; 2.10), c- section (PR = 2.65, 95%CI 2.17; 3.24) and Apgar scores < 7 at the 5th minute (PR = 2.96, 95%CI 2,94;2,99). Neonatal mortality was 1.6/1,000 live births. Meconium-stained amniotic fluid was found in 50% of neonatal deaths and it was associated with higher rates of surgical deliveries. CONCLUSIONS Oxytocin use, worse conditions of the newborn after the delivery and increased c-section rates were factors associated with meconium-stained amniotic fluid. Routine use of oxytocin in the intrapartum period could be evaluated due to its association with meconium-stained amniotic fluid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparison of Maternal Endometritis in Meconium – Stained Amniotic Fluid and Clear Amniotic Fluid

Introduction: Metritis is one of the causes of maternal morbidity and there are many risk factors for it. Because of the importance of possible association of meconium-stained amniotic fluid and maternal metritis the present study was done to determine whether meconium stained amniotic fluid (MSAF) is associated with puerperal infection. Methods: In this case-control study 150 women with MSAF a...

متن کامل

Study of prognostic factors for meconium-stained amniotic fluid

Introduction: meconium is the thick, Green - Black, with a bad odor material,  that founded around the third month of pregnancy in the intestines of fetus. 8 to 15 percent of infants has the evidence of meconium stained fluid at birth. In this study the factors affecting maternal and neonatal meconium-stained amniotic fluid be examined. Methods: This study was done in the Vali-e- asr hospital ...

متن کامل

Comparison of Neonatal Outcome with Meconium-Stained Amniotic Fluid in Normal Vaginal Delivery and Cesarean Section

Background and Objectives: Given the consequences and serious dangers, which threatens neonates born with meconium-stained amniotic fluid, and also due to the high prevalence of cesarean section, the present research was carried out with the aim of comparing the outcomes of neonates with meconium - stained amniotic fluid in vaginal delivery and cesarean section.   Methods: The present study wa...

متن کامل

بررسی عوامل خطرزای مادری و عوارض نوزادی در زایمان با مایع آمنیوتیک آغشته به مکونیوم و مایع آمنیوتیک شفاف

Background and Objective: Meconium Stained Amniotic Fluid (MSAF) is a common finding in term and post term pregnancies which has been taken into account as an unfavorable predictor of fetal and neonatal outcome. The aim of this study was to identify some maternal risk factors and neonatal complications in term pregnancies with meconium stained and clear amniotic fluid in Rasht Al Zahra Hospital...

متن کامل

Study on risk factors of meconium stained amniotic fluid and comparison of pregnancy outcome in clear and meconium stained amniotic fluid in a tertiary hospital, Kolkata, India

Keywords: Meconium stained amniotic fluid (MSAF) Pregnancy outcome Clear amniotic fluid (CAF) Original Article Objectives: To identify risk factors for meconium stained amniotic fluid (MSAF) and comparison of pregnancy outcome in meconium stained vs. clear amniotic fluid. Methods: The study was conducted at labor-room of IPGMER Hospital, Kolkata for consecutive 500 singleton deliveries at term ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista de saude publica

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2012