Analytical and clinical performance of a detergent-based homogeneous LDL-cholesterol assay: a multicenter evaluation.

نویسندگان

  • M Nauck
  • M S Graziani
  • D Bruton
  • C Cobbaert
  • T G Cole
  • F Lefevre
  • W Riesen
  • P S Bachorik
  • N Rifai
چکیده

BACKGROUND LDL-cholesterol (LDL-C) concentrations currently are determined in most clinical laboratories using the Friedewald calculation. This approach has several limitations and may not always meet the current total error recommendation in LDL-C measurement of </=12% established by the National Cholesterol Education Program. METHODS In a multicenter study, we evaluated the analytical and clinical performance of a homogeneous LDL-C assay (LDL-C(Roche); Roche Diagnostics, Indianapolis, IN) in a comparison with a beta-quantification method. RESULTS This direct assay correlated highly with a beta-quantification method (r = 0.968; y = 1.037x - 95.8 mg/L; n = 355; 95% confidence intervals, 1.011-1.063 for the slope and -129.5 to 62.0 mg/L for the y-intercept) and met the current total error requirement. The assay was not affected significantly by concentrations of hemoglobin up to 6000 mg/L or bilirubin up to 500 mg/L. However, a negative bias of 10% was seen when triglyceride concentrations exceeded 10 000 mg/L. At the medical decision cut-point range, the LDL-C(Roche) assay showed positive predictive values of 91-100% and negative predictive values of 80-99%. Furthermore, the clinical utility of the assay seemed unaffected in samples obtained postprandially. CONCLUSIONS The homogeneous LDL-C(Roche) assay meets the currently established analytical performance goals and may be useful for the diagnosis and management of hyperlipidemic patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of two different homogeneous assays for LDL-cholesterol in lipoprotein-X-positive serum.

BACKGROUND The purpose of this study was to evaluate the performance of two homogeneous assays for LDL-cholesterol (LDL-C), a polyethylene/cyclodextrin (PC) assay and a detergent (D) assay, which are based on different principles, in cholestatic serum. METHODS We compared serum LDL-C concentrations determined by the two assays for healthy normolipidemic subjects (n = 42) and cholestatic patie...

متن کامل

Analytical and clinical performance of a homogeneous enzymatic LDL-cholesterol assay compared with the ultracentrifugation-dextran sulfate-Mg2+ method.

LDL-cholesterol (LDL-C) concentration is currently determined in most clinical laboratories by the Friedewald calculation. This approach has several limitations and may not meet the current total error requirement in LDL-C measurement of < or = 12%. We evaluated the analytical and clinical performance of the direct N-geneous LDL-C assay (Equal Diagnostics). The N-geneous method correlated highl...

متن کامل

Improved specificity of a new homogeneous assay for LDL-cholesterol in serum with abnormal lipoproteins.

BACKGROUND Although a homogeneous assay for serum LDL-cholesterol (LDL-C) has become a routine clinical procedure, problems remain in assay performance characteristics. METHODS We examined the performance of a recently developed automated homogeneous assay (New-Daiichi assay) for serum LDL-C and compared the results with those obtained by the current homogeneous method (Denka-Seiken assay) or...

متن کامل

Effect of Specimen Anticoagulant and Storage on Mea- Surement of Serum and Plasma Fatty Acid

References 1. Adult Treatment Panel II. Summary of the second report of the National Cholesterol Education Program (NCEP) Expert Panel on Detection, Evaluation, and Treatment of High Blood Cholesterol in Adults (Adult Treatment Panel II). JAMA 1993;269:3015–23. 2. Havel R, Eder H, Bragdon J. The distribution and chemical composition of ultracentrifugally separated lipoproteins in human serum. J...

متن کامل

Evaluation of two homogeneous methods for measuring high-density lipoprotein cholesterol.

We evaluated the performance of two homogeneous assays for quantifying HDL cholesterol (HDL-C) and compared them with the phosphotungstic acid (PTA)/ MgCl2 assay. Both homogeneous HDL-C assays were precise, having a within-run CV of < 1.20% and a between-run CV of < 4.07%. The HDL-C values (y) measured by the two homogeneous methods correlated well with those by the PTA/MgCl2 method (x): y = 1....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 46 4  شماره 

صفحات  -

تاریخ انتشار 2000