Phase preparation in steady-state free precession MR elastography.

نویسندگان

  • Jens Rump
  • Carsten Warmuth
  • Jürgen Braun
  • Ingolf Sack
چکیده

Strain and motion measurements in balanced steady-state free precession (bSSFP) imaging require high magnetic field homogeneity. This requirement is due to the nonlinear signal response to spin phase variations in bSSFP. Here, a technique that utilizes background gradients for preparing strong in-plane spin phase variations is proposed. As a result, periodic patterns of increased motion sensitivity appear, which are interleaved with bands of low phase-to-noise ratio. Spatial filters commonly used in MR elastography (MRE) remove these bands and leave wave images equivalent to a uniform phase response in bSSFP-MRE. Since phase preparation gradients locally enhance motion sensitivity, the technique can be employed for selectively increasing the wave signal amplitude in MRE. The method is applied without the need for previous shimming, which reduces the examination time. In vivo phase prepared bSSFP-MRE is demonstrated in human liver and heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Nontriggered Cartesian steady-state free precession phase-contrast MR

Introduction: Nontriggered phase-contrast (PC)-MR has been proposed for measurement of time-averaged velocity [1]. However, gradient-echo PC-MR is biased by in-flow enhancement when typical flip angles and slice widths are used, leading to velocity overestimation [2]. We hypothesize that nontriggered PCsteady state free precession (SSFP), which exhibits less signal variation over the cardiac cy...

متن کامل

Shear wave group velocity inversion in MR elastography of human skeletal muscle.

In vivo quantification of the anisotropic shear elasticity of soft tissue is an appealing objective of elastography techniques because elastic anisotropy can potentially provide specific information about structural alterations in diseased tissue. Here a method is introduced and applied to MR elastography (MRE) of skeletal muscle. With this method one can elucidate anisotropy by means of two sh...

متن کامل

Time-Spatial Labeling Inversion Pulse: Safe, Simple and Effective Non-contrast MR Angiography

5. Shimada K, Isoda H, Okada T, et al. Noncontrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results. Eur J Radiol. 2009;70(1):111-117. 6. Shimada K, Isoda H, Okada T, et al. Non-contrast-enhanced MR portography with time-spatial labeling inversion pulses: comparison of imaging ...

متن کامل

Imaging periodic currents using alternating balanced steady-state free precession.

Existing functional brain MR imaging methods detect neuronal activity only indirectly via a surrogate signal such as deoxyhemoglobin concentration in the vascular bed of cerebral parenchyma. It has been recently proposed that neuronal currents may be measurable directly using MRI (ncMRI). However, limited success has been reported in neuronal current detection studies that used standard gradien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2008