Miniature intracardiac assist device provides more effective cardiac unloading and circulatory support during severe left heart failure than intraaortic balloon pumping.

نویسندگان

  • Koen D Reesink
  • André L Dekker
  • Vincent Van Ommen
  • Cecile Soemers
  • Gijs G Geskes
  • Frederik H van der Veen
  • Jos G Maessen
چکیده

BACKGROUND Hemodynamic assistance with a miniature intracardiac pump may fill the treatment gap between use of an intraaortic balloon pump (IABP) and the current, more invasive ventricular assist devices. The objective of this study was to compare the hemodynamic efficacy of a miniature intracardiac pump device with that of IABP. METHODS AND RESULTS Reversible acute mitral regurgitation (AMR) was induced in eight calves by stenting the mitral valve using a vena cava filter. Full and partial AMR assist were compared with maximum IABP support in each animal. In full-support mode, both assist systems increased cardiac output (miniature intracardiac pump, 13% [p < 0.05]; IABP, 3% [p < 0.05]), mean aortic pressure (miniature intracardiac pump, 13% [p < 0.05]; IABP, 8% [p < 0.05]), carotid artery flow (miniature intracardiac pump, 29% [p < 0.05]; IABP, 5% [difference not significant]), and coronary blood flow (miniature intracardiac pump, 25% [difference not significant]; IABP, 34% [p < 0.05]). Again in full-support mode, both systems reduced left atrial pressure (miniature intracardiac pump, 2.4 mm Hg [p < 0.05]; IABP, 0.7 mm Hg [p < 0.05]), peak left ventricular (LV) pressure (miniature intracardiac pump, 13% [p < 0.05]; IABP, 5% [p < 0.05]), and external LV work (miniature intracardiac pump, 29% [p < 0.05]; IABP, 3% [p < 0.05]). Only full miniature intracardiac pump support reduced both end-diastolic LV volume (7%; p < 0.05) and end-systolic LV volume (10%; p < 0.05). IABP mainly improved coronary perfusion, while the miniature intracardiac pump proved more capable of genuinely unloading the LV. CONCLUSIONS We conclude that during severe acute LV failure, the miniature intracardiac pump is capable of more effective cardiac unloading and circulatory support than IABP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous left ventricular assist devices in acute myocardial infarction complicated by cardiogenic shock.

Cardiogenic shock (CS) remains the most common cause of death in patients with acute myocardial infarction (AMI). In addition to percutaneous coronary intervention, inotropes, and fluids, intraaortic balloon pumping (IABP) is most widely used for initial haemodynamic stabilization. However, the main limitation of IABP is the lack of active circulatory support and the requirement of a certain le...

متن کامل

End Stage Heart Failure – Transplantation or Lvad?

Heart failure is a complex clinical syndrome that can result from any structural or functional cardiac disorder that impairs the ability of the ventricle to fill or eject blood. According to the data from the International Society for Heart and Lung Transplantation registry, the half-life of patient survival after heart transplantation has progressively improved from 8.9 years in 1982 to a proj...

متن کامل

Prolonged use for at least 10 days of intraaortic balloon pumping (IABP) for heart failure.

Intraaortic balloon pumping (IABP) is a useful therapy for refractory heart failure. However, the safe duration of this therapy and possible complications due to long-term IABP support remain unclear. In this study, we reviewed retrospectively patients requiring the long-term use of IABP, defined here as 10 days or more, to estimate the background and prognosis of patients undergoing long-term ...

متن کامل

A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock.

BACKGROUND AND AIM Despite major advances in the treatment of heart failure, cardiogenic shock (CGS) remains associated with substantial mortality. Recent data suggest that the TandemHeart percutaneous ventricular assist device (pVAD) may be useful in the management of CGS. The aim of this prospective randomized study was to test the hypothesis that the TandemHeart (pVAD) provides superior hemo...

متن کامل

Intraaortic Balloon Counterpulsation and Other Circulatory Assist Devices

conditions, the availability of effective devices for circulatory support has assumed increasing importance. The first such device was the (IABP), which improved the myocardial oxygen supply/demand ratio and provided limited circulatory support. It remains the most widely used and practical system today, although more complicated devices, such as the left ventricular support device (LVAD) and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 126 3  شماره 

صفحات  -

تاریخ انتشار 2004