Carbon Dioxide Flushing Technique to Prevent Cerebral Arterial Air Embolism and Stroke During TEVAR.
نویسندگان
چکیده
PURPOSE To describe the technique of carbon dioxide (CO2) flushing of thoracic stent-grafts to reduce the risk of cerebral air embolism. TECHNIQUE To remove room air, thoracic stent-grafts were preoperatively flushed 2 minutes with carbon dioxide from a cylinder connected to the flushing chamber of the captor valves of Zenith custom-made endografts; this was followed by the standard saline flush. Thirty-six patients undergoing thoracic endovascular aortic repairs (TEVAR) involving the ascending aorta and the aortic arch received CO2-flushed Zenith endografts. One patient with a highly calcified arch experienced a minor stroke. CONCLUSION Arterial air embolism is a potentially underappreciated problem of aortic endografting, especially in the proximal segments of the aorta. CO2 flushing may have the potential to reduce air embolization during TEVAR.
منابع مشابه
Use of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملAir Pollution Is Associated With Ischemic Stroke via Cardiogenic Embolism.
BACKGROUND AND PURPOSE The aim of the study was to assessed the impact of short-term exposure to air pollution on ischemic stroke subtype, while focusing on stroke caused via cardioembolism. METHODS From a nationwide, multicenter, prospective, stroke registry database, 13 535 patients with acute ischemic stroke hospitalized to 12 participating centers were enrolled in this study. Data on the ...
متن کاملCerebral Gas Embolism - A Serious Complication of CO2 Angiography
Carbon dioxide angiography is routinely used for vascular imaging and endovascular procedures. It is very useful in patients with allergy to iodinated contrast agents or with poor renal function. It is relatively safe to use. We describe first case of cerebral gas embolism leading to multiple bilateral ischemic strokes in a patient receiving carbon dioxide angiography for workup of thrombosed a...
متن کاملMultiple cerebral infarction and paradoxical air embolism during hepatectomy using the Cavitron Ultrasonic Surgical Aspirator -A case report-
A venous air embolism and paradoxical air embolism (PAE) are serious complications in patients undergoing a hepatectomy. We report a case of PAE and cerebral infarctions in a patient undergoing a hepatic resection using a Cavitron Ultrasonic Surgical Aspirator (CUSA®). A 65-year-old woman underwent a left lobe hepatectomy. During the middle phase of the liver resection with CUSA®, there was a s...
متن کاملAcute stroke from air embolism to the middle cerebral artery following upper gastrointestinal endoscopy
Acute stroke from cerebral-artery air embolism is a very rare occurrence during esophagogastroduodenoscopy (EGD). Computed tomography is a quick and reliable method of detecting cerebral air embolism if performed within an appropriate timeframe. We found 20 reported cases of air embolism with EGD in the literature; only seven of those resulted in cerebral air embolus. We report an eighth such c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
دوره 23 2 شماره
صفحات -
تاریخ انتشار 2016