Field evaluation of malaria rapid diagnostic tests for the diagnosis of P. falciparum and non-P. falciparum infections.
نویسندگان
چکیده
The objective of this study was to evaluate various malaria rapid diagnostic tests as a tool in the detection of P. falciparum and non-P. falciparum infections in field conditions. Four field surveys were conducted in malaria-endemic areas of Palawan and Davao del Norte, Philippines to validate the various rapid diagnostic tests, namely Diamed OptiMAL 48 (DiaMed AG, Switzerland), ParaHIT f (Span Diagnostics, India), Orchid OptiMAL, and Paracheck Pf (both from Orchid Biomedical Systems, India). The results of the various rapid diagnostic tests were compared to those of microscopy. Sensitivity, specificity and detection rates according to the level of parasitemia were used as parameters to describe the performance of the various rapid diagnostic tests in the field. Practical and operational assessments were also done. The results of the study show that the sensitivity and detection rates were generally lower than previously reported, with sensitivities ranging from 4.8% to 20.6%, except for Diamed OptiMAL 48, which had sensitivities of 78.8% to 96.8%, and detection rates of 50.0% to 96.8%. The rest had detection rates ranging from 0.0% to 50.0%. All the specificities ranged from 18.2% to 100.0%. Improper conditions at the time of manufacturing, storage, transport, and utilization may affect the validity of the results. Rapid diagnostic tests for malaria provide practical means of detecting malarial infections, especially in endemic areas. However, issues regarding variability in performance must to be addressed before they can be used as mainstream diagnostic tools.
منابع مشابه
Molecular Evidence on Changing Pattern of Mixed Plasmodium falciparum and P. vivax Infections during Year-Round Transmission of Malaria in Chahbahar, Iran
Mixed malaria infections, Plasmodium falciparum and P. vivax, are suspected to occur at a greater frequency than is detected by conventional light microscopy. In order to determine the year round pattern of transmission and the frequency of mixed infections in malaria endemic area, we carried out a prospective comparison of diagnosis by conventional light microscopy and nested PCR in Chahbahar ...
متن کاملEvaluation of Microscopy Sensitivity, Specificity in Detection of P. falciparum and P. vivax, Using Monoplex real-time PCR, Gezira, Sudan
Background: Malaria is still account for 200 million cases annually. Microscopy is the gold standard technique for malaria parasites detection. PCR-based techniques can detect malaria infections with high sensitivity. The study aimed to evaluate the sensitivity of microscopy technique in the detection of P. falciparum and P. vivax, using monoplex real-time PCR, Gezira State, Central Sudan. Met...
متن کاملLow sensitivity of malaria rapid diagnostic tests stored at room temperature in the Brazilian Amazon Region.
INTRODUCTION In remote areas of the Amazon Region, diagnosis of malaria by microscopy is practically impossible. This study aimed to evaluate the performance of two rapid diagnostic tests (RDTs) targeting different malaria antigens stored at room temperature in the Brazilian Amazon Region. METHODOLOGY Performance of the OptiMal Pf/Pan test and ICT-Now Pf/Pan test was analyzed retrospectively ...
متن کاملDiagnostic Performance Evaluation of the Sd Bioline Malaria Antigen Ag Pf/pan Test (05fk60) in a Malaria Endemic Area of Southern Ethiopia
Rapid diagnostic tests (RDTs) capable of detecting and differentiating Plasmodium species are needed in areas in which microscopy is unsuitable. This study was conducted to assess the diagnostic performance of the rapid test kit - SD BIOLINE Malaria Ag Pf/Pan(r) (05FK60) in an endemic area. Microscopy of Giemsa-stained blood films were performed to detect and estimate the Plasmodium density in ...
متن کاملEvaluation of the Accuracy of the EasyTest™ Malaria Pf/Pan Ag, a Rapid Diagnostic Test, in Uganda
In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Southeast Asian journal of tropical medicine and public health
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2005