Combined volar and dorsal plating for complex comminuted distal radial fractures.
نویسندگان
چکیده
PURPOSE To review outcomes of combined volar and dorsal locked plating for AO type-C3 complex comminuted distal radial fractures. METHODS Records of 24 patients aged 17 to 77 (mean, 53.3) years who underwent combined volar and dorsal locked plating for AO type-C3 distal radial fractures with volar and dorsal metaphyseal and intra-articular comminution were reviewed. 21 were closed fractures, and 3 were Gustilo-Anderson type-1 open fractures. Bone union, volar tilt, radial inclination, radial height, range of motion, grip strength, and any complications were assessed by a single hand surgeon. RESULTS After a mean follow-up of 17 (range, 14-25) months, the mean palmar flexion was 49º (range, 30º-80º), dorsiflexion was 52º (range, 30º-80º), supination was 86º (range, 60º-90º), pronation was 77º (range, 30º-90º), radial deviation was 16º (range, 5º-30º), and ulnar deviation was 27º (range, 10º-50º). The mean grip strength of the injured hand was 69.2% of the uninjured side. The mean time to radiological union was 3.9 (range, 2.5-6.0) months; no patient had non-union. At the time of union, the mean volar tilt was 5º (-22º-14º), radial inclination was 18.6º (8º-28º), and radial height was 8.5 mm (5.0 mm-13.6 mm). One patient had collapse of the dorsal fragment resulting in a dorsal tilt of 22º and limited (30º) forearm pronation. The severity of dorsal metaphyseal comminution had not been recognised and bone grafting was not performed. The patient also had minor complications of little finger flexor tendon irritation and carpal tunnel syndrome. She underwent implant removal and carpal tunnel release at 8 months. One patient had implant-related extensor digitorum communis irritation. Another patient had non-specific chronic wrist pain, which was resolved at one year. No patient had infection, tendon rupture, or complex regional pain syndrome. Four patients underwent implant removal, including 2 who had no implant-related problems. CONCLUSION Combined volar and dorsal plating enables early mobilisation and good outcome for certain complex comminuted distal radial fractures.
منابع مشابه
Various volar shapes of the distal radius and its implications on volar plate osteosynthesis
Volar plate fi xation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variati...
متن کاملAnatomy of the distal volar radius and its implications on volar plate osteosynthesis
Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variatio...
متن کاملInternal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.
BACKGROUND Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted extra-articular distal radial fractures. The purpose of the present study was to compare the relative stability of five distal radial plates (four volar and one dorsal), all of which are commonly used for the treatme...
متن کاملRepositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique
BACKGROUND A possible difficulty in intra-articular fracture of the distal radius is the displacement tendency of the radial styloid process due to the tension of the brachioradialis tendon. METHODS Ten patients treated within one year for complex distal radius fractures by double-plating technique with a radial buttress plate and volar locking plate, through a single volar approach, were fol...
متن کاملTen Years’ Follow-Up on Combined Palmar and Dorsal Internal Fixation of Complex Distal Radius Fractures
Complex distal intra-articular radial fractures (AO Type C3) are rare, but are life-changing injuries. They are usually related to high-velocity trauma mechanisms in a working male population.We surveyed a cohort of these fractures treated in our institution to assess the functional long-term outcome.Twelve consecutive patients with comminuted intra-articular distal radial fractures were treate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic surgery
دوره 23 1 شماره
صفحات -
تاریخ انتشار 2015