MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique.

نویسندگان

  • H Langreck
  • B Schnackenburg
  • K Nehrke
  • P Boernert
  • A Wahl
  • I Paetsch
  • A Bornstedt
  • E Fleck
  • Eike Nagel
چکیده

Magnetic resonance coronary angiography (MRCA) has been proven to be feasible for imaging of the proximal and medial portions of the three main coronary arteries. Free breathing techniques allow for high resolution imaging but prolong scan time. This could potentially be shortened by improving the efficiency, robustness and accuracy of the navigator gating algorithm. Aim of this study was to determine the feasibility, efficiency, and image quality of a new motion compensation algorithm (3D-MAG) for coronary artery imaging with navigator techniques. In 21 patients the coronaries were imaged in plane with a 3D k-space segmented gradient echo sequence. A T2 preparation prepulse was used for suppression of myocardial signal, during free breathing and a navigator technique with using real time slice following and a gating window of 5 mm was applied to suppress breathing motion artefacts. Imaging was performed with standard gating and compared to 3D-MAG. Image quality was visually compared, contrast-to-noise and signal-to-noise ratio were calculated, the length of visualized coronary arteries was measured and scan duration and scan efficiency were calculated. Standard navigator imaging was feasible in 19 of 21 (90.5%) patients 3D-MAG in 21/21 (100%). Scan efficiency and duration was significantly improved with 3D-MAG (p < .05) without change in image quality. 3D-MAG is superior to conventional navigator correction algorithms. It improves feasibility and scan efficiency without reduction of image quality. This approach should be routinely used for MR coronary artery imaging with navigator techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High resolution, free-breathing coronary artery imaging with >99% respiratory efficiency: comparing beat to beat respiratory motion correction with navigator gating

Introduction: High-resolution coronary artery imaging is commonly gated to end-expiration using diaphragmatic navigator echoes, resulting in inherently low respiratory efficiency (RE) which is further exacerbated by respiratory drift. Recently, it was demonstrated that epicardial fat can be used as a marker of coronary artery position in a 3D beat-to-beat non-model based subject-specific respir...

متن کامل

Direct monitoring of coronary artery motion with cardiac fat navigator echoes.

Navigator echoes (NAVs) provide an effective means of monitoring physiological motion in magnetic resonance imaging (MRI). Motion artifacts can be suppressed by adjusting the data acquisition accordingly. The standard pencil-beam NAV has been used to detect diaphragm motion; however, it does not monitor cardiac motion effectively. Here we report a navigator approach that directly measures coron...

متن کامل

High resolution 3D spiral coronary vessel wall imaging with >99% respiratory efficiency using beat to beat respiratory motion correction: quantitative comparison with navigator gated 2D spiral and turbo spin echo imaging

Introduction: Dark blood coronary artery wall imaging has demonstrated the ability to detect vessel wall thickening in subjects with non-significant coronary heart disease [1]. For high resolution imaging, studies are generally performed with diaphragmatic navigator gating which has an inherently low respiratory efficiency (RE) and is further compromised by respiratory drift through the long ac...

متن کامل

Simulation Tool for k-Space Reordering in Free-Breathing Navigator-Gated 3D Coronary MRA

In coronary MR angiography (MRA) breathing motion during data acquisition may result in image artifacts. One solution is the use of MR navigators to gate to the respiratory cycle, but the use of narrow gating windows often lead to prolonged/time inefficient scans. Therefore sophisticated k-space reordering techniques 1, 2 have been proposed to reduce motion artifacts in free-breathing navigator...

متن کامل

High-resolution 3D coronary vessel wall imaging with near 100% respiratory efficiency using epicardial fat tracking: reproducibility and comparison with standard methods.

PURPOSE To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. MATERIALS AND METHODS High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2005