Acute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead.

نویسندگان

  • Bernard Thibault
  • Marc Dubuc
  • Paul Khairy
  • Peter G Guerra
  • Laurent Macle
  • Lena Rivard
  • Denis Roy
  • Mario Talajic
  • Edward Karst
  • Kyungmoo Ryu
  • Patrice Paiement
  • Taraneh G Farazi
چکیده

AIMS Pacing from multiple sites in the left ventricle (LV) may bring about further resynchronization of the diseased heart compared with biventricular (BiV) pacing. We compared acute haemodynamic response (LV dP/dtmax) of multisite and BiV pacing using a quadripolar LV lead. METHODS AND RESULTS In 21 patients receiving cardiac resynchronization therapy, a quadripolar LV lead and conventional right atrial and ventricular leads were connected to an external pacing system. A guidewire pressure sensor was placed in the LV for continuous dP/dt measurement. Four multisite pacing configurations were tested three times each and compared with BiV pacing using the distal LV electrode. Nineteen patients had useable haemodynamic data. Median increase in LV dP/dtmax with BiV vs. atrial-only pacing was 8.2% (interquartile range 2.3%, 15.7%). With multisite pacing using distal and proximal LV electrodes, median increase in LV dP/dtmax was 10.2% compared with atrial-only pacing (interquartile range 6.1%, 25.6%). In 16 of 19 patients (84%), two or more of the four multisite pacing configurations increased LV dP/dtmax compared with BiV pacing. Overall, 72% of all tested configurations of multisite pacing produced greater LV dP/dtmax than obtained with BiV pacing. Pacing from most distal and proximal electrodes was the most common optimal configuration, superior to BiV pacing in 74% of patients. CONCLUSION In the majority of patients, multisite pacing improved acute systolic function further compared with BiV pacing. Pacing with the most distal and proximal electrodes of the quadripolar LV lead most commonly yielded greatest LV dP/dtmax.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of left ventricular endocardial, multisite, and multipolar epicardial cardiac resynchronization: an acute haemodynamic and electroanatomical study.

AIMS Alternative forms of cardiac resynchronization therapy (CRT), including biventricular endocardial (BV-Endo) and multisite epicardial pacing (MSP), have been developed to improve response. It is unclear which form of stimulation is optimal. We aimed to compare the acute haemodynamic response (AHR) and electrophysiological effects of BV-Endo with MSP via two separate coronary sinus (CS) lead...

متن کامل

Quadripolar Leads in Cardiac€Resynchronization Therapy

Ma Despite the benefit of cardiac resynchronization therapy (CRT) in patients with heart failure and conduction delay, a considerable number of patients do not respond substantially. Left ventricular lead position is an important factor in response, restricted by the patient’s specific anatomy and local pathophysiology. Quadripolar leads could enhance response to CRT, offering 4 pacing location...

متن کامل

The Use of a Quadripolar Left Ventricular Lead Increases Successful Implantation Rates in Patients with Phrenic Nerve Stimulation and/or High Pacing Thresholds Undergoing Cardiac Resynchronisation Therapy with Conventional Bipolar Leads

BACKGROUND Phrenic nerve stimulation (PNS) and high pacing thresholds (HPT) hinder biventricular stimulation in patients (pts) undergoing cardiac resynchronization therapy (CRT). A new quadripolar left ventricular (LV) lead (Quartet 1458Q, St. Jude Medical) with increased number of pacing configuration, might overcome this problem. METHODS All consecutive pts in whom a standard bipolar lead i...

متن کامل

Quadripolar Left Ventricular Lead in a Patient with CRT-D Does Not Overcome Phrenic Nerve Stimulation

Effective cardiac resynchronization therapy (CRT) requires an accurate atrio-biventricular pacing system. The innovative Quartet lead is a quadripolar, over-the-wire left ventricular lead with four electrodes and has recently been designed to provide more options and greater control in pacing vector selection. A lead with multiple pacing electrodes is a potential alternative to physical adjustm...

متن کامل

Comparison of permanent left ventricular and biventricular pacing in patients with heart failure and chronic atrial fibrillation: prospective haemodynamic study.

OBJECTIVE To compare clinical and haemodynamic variables between left ventricular and biventricular pacing in patients with severe heart failure; and to analyse haemodynamic changes during daily life and maximum exercise during chronic left ventricular and biventricular pacing. DESIGN Prospective single blinded randomised study with crossover. SETTING University hospital (tertiary referral ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 15 7  شماره 

صفحات  -

تاریخ انتشار 2013