The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial

نویسندگان

  • Ah-Young Oh
  • Young-Tae Jeon
  • Eun-Joo Choi
  • Jung-Hee Ryu
  • Jung-Won Hwang
  • Hee-Pyoung Park
  • Sang-Hwan Do
چکیده

BACKGROUND It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compared to landmark method. METHODS Sixty adult patients who required subclavian venous catheterization for neurosurgery were enrolled in this prospective randomized controlled study. Patients were randomly divided into a landmark group (n = 30) or an ultrasound group (n = 30). After the subclavian vein was punctured, the guidewire was advanced with the guidewire J-tip directed cephalad. Misplacement or advancement failure of the guidewire was regarded as an unsuccessful placement. Postoperative chest radiography was performed to confirm pneumothorax and the location of the catheter tip. RESULTS The two groups were comparable with respect to age, gender, height, and weight distribution. The incidence of unsuccessful guidewire placement was lower in the ultrasound group than in the landmark group (13% vs. 47%, P = 0.01). Among the unsuccessful guidewire placements, the incidence of misplacement were comparable between the groups and were all located in the ipsilateral internal jugular vein (7% vs. 7%). However, the incidence of advancement failure was significantly higher in landmark group (40% vs. 7%, P = 0.005). There were no complications such as pneumothorax or hemothorax. CONCLUSIONS The proper placement of guidewire was less influenced by the direction of the guidewire J-tip with ultrasound-guided subclavian venous cannulation than with the landmark approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial

BACKGROUND Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid an...

متن کامل

Real-time ultrasound-guided subclavian vein cannulation versus the landmark method in critical care patients: a prospective randomized study.

OBJECTIVE Subclavian vein catheterization may cause various complications. We compared the real-time ultrasound-guided subclavian vein cannulation vs. the landmark method in critical care patients. DESIGN Prospective randomized study. SETTING Medical intensive care unit of a tertiary medical center. PATIENTS Four hundred sixty-three mechanically ventilated patients enrolled in a randomize...

متن کامل

The real effectiveness of ultrasound guidance in subclavian venous access.

AIM The technique of ultrasound-guided subclavian cannulation was evaluated in our experience assessing the real effectiveness of such procedure. METHODS We have evaluated 297 subclavian cannulation, performed for the placement of central venous catheter both with landmark method (176 patients) and ultrasound guided technique (121 patients) to assess the real effectiveness of the ultrasound-g...

متن کامل

Tracheal intubation in the critically ill: just say no to drugs.

vein location: impact of central venous access. Crit Care Med 1991; 19: 1516–9 3 Sulek CA, Gravenstein N, Blackshear RH, Weiss L. Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture. Anesth Analg 1996; 82: 125–8 4 Reuber M, Dunkley LA, Turton EPL, Bell MDD, Bamford JM. Stroke after internal jugular venous cannulation. Acta Neurol Scand 2002; 105: 235–9...

متن کامل

Ultrasonic locating devices for central venous cannulation: meta-analysis.

OBJECTIVES To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. DATA SOURCES 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. DESIGN Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVEN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014