Technique for placement of oxidized titanium implants in compromised maxillary bone: prospective study of 290 implants in 126 consecutive patients followed for a minimum of 3 years after loading.
نویسنده
چکیده
PURPOSE This prospective clinical study evaluated the performance of 290 tapered, anodic oxidized (TiUnite) titanium implants placed in compromised bone in a consecutive series of 126 patients. MATERIALS AND METHODS Inclusion criteria were: (1) a need for dental implants in either a single-tooth or partially edentulous segment, (2) sufficient medical fitness to undergo the procedure, (3) enough bone to enable placement of a 10-mm or longer implant, and (4) compromised bone, as judged by computerized tomography and confirmed by clinical findings, in at least one implant site. Implants were placed and left unloaded for at least 6 months (mean 9.9 +/- 3.9 months) before placement of the first provisional prosthesis and followed for at least 3 years after loading. Marginal bone was measured by an independent radiologist. RESULTS A second-stage uncovering was required for approximately half the implants. Failure of osseointegration was observed for only two implants; all other implants provided the intended prosthetic support during the entire observation period. The overall implant survival rate after 3 years of loading was 99.3%. The average mean changes in the marginal bone level showed stability (-2.70 mm, -2.67 mm, and -2.74 mm at 1, 2, and 3 years postloading, respectively). CONCLUSIONS Using a modified surgical technique that minimized the osteotomy dimensions, tapered implants with an oxidized surface proved to be a predictable support for fixed prostheses in both grafted and ungrafted compromised bone. Marginal bone levels were stable throughout at least 3 years of follow-up.
منابع مشابه
Outcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial
Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...
متن کاملClinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کاملThe self-tapping and ICE 3i implants: a prospective 3-year multicenter evaluation.
This multicenter prospective clinical evaluation was undertaken to determine the therapeutic success and marginal bone level stability of 3i's self-tapping and ICE implants after 3 years of prosthetic loading. Between July 1995 and June 1996, 189 completely or partially edentulous patients were treated with 614 machined-surface screw-type commercially pure titanium implants (self-tapping or ICE...
متن کاملSuccess rate of immediate loading of single OPILS implants of Neo-Dent system
Success rate of immediate loading of single OPILS implants of Neo-Dent system Dr. SH. Namjoy Nik * - Dr. SH. Shahab ** - Dr. M. Mohammad Poor*** - Dr. A. Balooch*** *- Assistant Professor of Oral and Maxillofacial Surgery Dept. - Faculty of Dentistry – Shahed University. **- Assistant Professor of Oral Radiology Dept. Faculty of Dentistry – Shahed University. ***- Dentist. Background and Aim: I...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2009