Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector.

نویسندگان

  • G A Eiceman
  • E G Nazarov
  • R A Miller
  • E V Krylov
  • A M Zapata
چکیده

A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro-structured electron accelerator for the mobile gas ionization sensor technology

Mobile and economically priced gas monitoring and warning systems will become increasingly important for civil security, such as in fire brigade operations in undefined hazardous environments (Daum et al., 2006). Normally, photoionization detectors (PIDs) are used for the detection of gases. Hereby, the principle is based upon the ionization of the measured gas by photons, which are generated b...

متن کامل

Separation of opiate isomers using electrospray ionization and paper spray coupled to high-field asymmetric waveform ion mobility spectrometry.

One limitation in the growing field of ambient or direct analysis methods is reduced selectivity caused by the elimination of chromatographic separations prior to mass spectrometric analysis. We explored the use of high-field asymmetric waveform ion mobility spectrometry (FAIMS), an ambient pressure ion mobility technique, to separate the closely related opiate isomers of morphine, hydromorphon...

متن کامل

Characterization of ion processes in a GC/DMS air quality monitor by integration of the instrument to a mass spectrometer.

The air quality monitor (AQM), which included a portable gas chromatograph (GC) and a detector was interfaced to a mass spectrometer (MS) by introducing flow from the GC detector to the atmospheric pressure ion source of the MS. This small GC system, with a gas recirculation loop for carrier and detector make-up gases, comprised an inlet to preconcentrate volatile organic compounds (VOCs) in ai...

متن کامل

High sensitivity field asymmetric ion mobility spectrometer.

A high sensitivity field asymmetric ion mobility spectrometer (FAIMS) was designed, fabricated, and tested. The main components of the system are a 10.6 eV UV photoionization source, an ion filter driven by a high voltage/high frequency n-MOS inverter circuit, and a low noise ion detector. The ion filter electronics are capable to generate square waveforms with peak-to-peak voltages up to 1000 ...

متن کامل

Discrimination of combustion fuel sources using gas chromatography-planar field asymmetric-waveform ion mobility spectrometry

a) Department of Chemistry and Biochemistry ([email protected]), New Mexico State University, Las Cruces, NM 88003 USDA-ARS-SW Cotton Ginning Research Lab ([email protected]), 300 E. College Drive, PO Box 578, Mesilla Park, NM 88047 c) SIONEX Corporation ([email protected]), 300 Second Ave., Waltham, MA 02451 Discrimination of combustion fuel sources using gas chromatography-planar field asymmetr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 127 4  شماره 

صفحات  -

تاریخ انتشار 2002