Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts
نویسندگان
چکیده
BACKGROUND Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. MATERIALS AND METHODS Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left first premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated (n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the definitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t-test (α = 0.05). RESULTS No statistical significant differences were observed between different impression techniques and materials. However, deviation and distortion of definitive casts had a significant difference with the master model when short impression copings and polyvinyl siloxane impression material were used (P < 0.05). In open tray technique, there was a significant difference in the rotation of analogs compared with the master model with both impression materials (P < 0.05). CONCLUSION There was no difference between open and closed tray impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings.
منابع مشابه
Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis.
PURPOSE To assess the three-dimensional (3D) accuracy and clinical acceptability of implant definitive casts fabricated using a digital impression approach and to compare the results with those of a conventional impression method in a partially edentulous condition. MATERIALS AND METHODS A mandibular reference model was fabricated with implants in the first premolar and molar positions to sim...
متن کاملEffects of Water/Powder Ratio of Irreversible Hydrocolloid on Dimensional Stability of Impressions
Background and Aim: Water/powder ratio is effective on some properties of irreversible hydrocolloid impression materials. This study aimed to determine the ef-fects of water/powder ratio of irreversible hydrocolloid impression materials on di-mensional stability of impressions. Materials and Methods: In this in vitro experimental study, a metal model with two abutments as anchoring support for...
متن کاملEffect of Three Disinfectants on Dimensional Changes of Different Impression Materials
Background and Aim: Disinfection of dental impression materials can alter their dimensional stability, which in turn can affect the accuracy of dental casts. This study aimed to determine the effect of three disinfectants on the dimensional changes of ir-reversible hydrocolloid impression materials and addition silicones. Materials and Methods: Forty alginate and 40 addition silicone impressio...
متن کاملComparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD
Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...
متن کاملAccuracy of impressions with different impression materials in angulated implants.
PURPOSE To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. MATERIALS AND METHODS Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were ...
متن کامل