Effect of Vacuum on the Performance of the Flame Ionization DetectorUsed for Vacuum-Outlet Gas Chromatography

نویسندگان

  • Ulrich R. Bernier
  • Christopher L. Bray
  • Richard A. Yost
چکیده

Vacuum-outlet operation of short fused-silica open tubular columns for gas chromatography provides benefits to analysis speed by increasing the optimum velocity while minimizing the loss in resolution. Vacuum-outlet operation of a column with a gas chromatographic detector necessitates that the detector also be under vacuum. Simple modifications were made to a gas chromatograph]flame Ž . ionization detector GC]FID for vacuum-inlet and vacuum-outlet operation. The vacuum-inlet system was operated in the splitless mode to allow for efficient sample loading prior to operation at reduced pressures. The goal of FID operation at 100 torr or less was achieved by using oxygen in place of air and optimizing the gas flows under vacuum to maintain a stable flame at pressures as low as 46 torr. An outlet pressure of 85 torr with optimized gas flows allowed for routine operation of the FID without solvent flame-out. It was discovered that the sensitivity is enhanced compared to atmospheric operation over a range of outlet pressures from approximately 200 to 400 torr; however, operation of the FID at the lowest possible pressures decreases the analytical sensitivity due to both the outlet pressure and the absence of helium makeup gas. Q 2000 John Wiley & Sons, Inc. J Micro Sep 12: 226]235, 2000

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Design and Simulation of Hot Cathode Ionization Vacuum Gauge with no X-Ray Limitations

In this paper, the MEMS type ionization gauge with no X-Ray limitations has been presented. Having the dimensions of 2.4 mm× 0.8mm × 1.4 mm, the designed gauge is 9000 times smaller than the conventional type and can operate in HV and UHV pressures up to 5×10-9 torr. Operating at the temperature of 750°C, the cathode of proposed gauge is implemented using nickel and works in a way in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017