Shotgun lipidomic analysis of chemically sulfated sterols compromises analytical sensitivity: Recommendation for large-scale global lipidome analysis

نویسندگان

  • Albert Casanovas
  • Hans Kristian Hannibal-Bach
  • Ole N Jensen
  • Christer S Ejsing
چکیده

Shotgun lipidomics affords comprehensive and quantitative analysis of lipid species in cells and tissues at high‐ throughput [1–5]. The methodology is based on direct infusion of lipid extracts by electrospray ionization (ESI) combined with tandem mass spectrometry (MS/MS) and/or high resolution Fourier transform mass spectrometry (FTMS) for identification and quantification of lipid species [6]. Shotgun lipidomics affords extensive lipidome coverage by combining the analysis of lipid extracts in positive and negative ion mode [1, 3]. Notably, sterols such as cholesterol and ergosterol exhibit low ionization efficiency in ESI [7]. For this reason, chemical derivatization procedures including acetylation [8] or sulfation [9] are commonly implemented to facilitate ionization, detection and quantification of sterols for global lipidome analysis [1–3, 10]. In the course of large‐scale lipidomic analyses using an LTQ Orbitrap XL mass spectrometer (Thermo Scientific) equipped with a robotic nanoESI source TriVersa NanoMate (Advion Biosciences), we observed a pronounced decrease in the sensitivity of negative ion mode analysis following repeated injections of samples subjected to chemical sulfation. This decrease in sensitivity was observed only for negative ion mode analysis of lipid species in underivatized lipid extracts. No decrease in sensitivity was observed for negative ion mode analysis of chemically sulfated sterols or for positive ion mode analysis of lipid species in underivatized lipid extracts. To investigate the decrease in analytical sensitivity in further detail we (i) spiked a yeast lysate with internal standards and executed two‐step lipid extraction as previously described [3] for the partition of apolar and polar lipids, (ii) subjected the apolar lipid extract (containing sterols) to chemical sulfation [2, 9], and (iii) infused the sulfated sample in batches of ten repeated injections and monitored the intensity of chemically sulfated sterols by negative ion mode FTMS. To monitor the decrease in sensitivity we analyzed the underivatized polar lipid extract [containing phosphatidylinositol (PI) as well as other polar lipids [3]] by negative ion mode FTMS before and after each batch of ten repeated injections of the sulfated sample. This analysis showed a progressive loss of sensitivity for negative ion mode analysis of lipid species in the underivatized polar lipid extract. To exemplify this effect, the intensity of PI 34:1, an abundant glycerophospholipid species in yeast [3, 10], was reduced more than 20‐fold after 30 injections of the sulfated sample (Fig. 1a). More importantly, since an intensity threshold is routinely used in shotgun lipidomics data processing [11], the decrease in sensitivity translated into a decrease in the number of lipid species identified and quantified (data not shown). Notably, the intensity of chemically sulfated sterols was unaffected (Fig. 1b). As we had previously observed that the sensitivity of positive ion mode analysis was not affected, we transiently switched the polarity to positive for 1 h and subsequently reverted it to evaluate whether the sensitivity of negative ion mode analysis was restored. This polarity switch partially restored the sensitivity (>40%, in the case of PI 34:1) for negative ion mode analysis of lipid species in the underivatized polar lipid extract (Fig. 1a). Based on these results, we recommend that global shotgun lipidomic experiments employing chemical sulfation of sterols use a specific sequence of MS analyses where the analysis of sulfated samples is scheduled at the end of all other analyses in order not to compromise analytical sensitivity (Fig. 2). In conclusion, here we: (i) demonstrate that shotgun lipidomic analysis of sample extracts subjected to chemical sulfation can prompt a pronounced loss of sensitivity for negative ion mode analysis of underivatized lipid extracts; Correspondence: Christer S. Ejsing, Department of Biochemistry and Molecular Biology, University of Southern Denmark, Campusvej 55, 5230 Odense, Denmark E‐mail: [email protected] Fax: þ45 655

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large-scale human skin lipidomics by quantitative, high-throughput shotgun mass spectrometry

The lipid composition of human skin is essential for its function; however the simultaneous quantification of a wide range of stratum corneum (SC) and sebaceous lipids is not trivial. We developed and validated a quantitative high-throughput shotgun mass spectrometry-based platform for lipid analysis of tape-stripped SC skin samples. It features coverage of 16 lipid classes; total quantificatio...

متن کامل

Correction: Analysis of Lipid Experiments (ALEX): A Software Framework for Analysis of High-Resolution Shotgun Lipidomics Data

Global lipidomics analysis across large sample sizes produces high-content datasets that require dedicated software tools supporting lipid identification and quantification, efficient data management and lipidome visualization. Here we present a novel software-based platform for streamlined data processing, management and visualization of shotgun lipidomics data acquired using high-resolution O...

متن کامل

High-Throughput and Comprehensive Lipidomic Analysis Using Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry.

New analytical approach for high-throughput and comprehensive lipidomic analysis of biological samples using ultrahigh-performance supercritical fluid chromatography (UHPSFC) with electrospray ionization-mass spectrometry (ESI-MS) is presented in this work as an alternative approach to established shotgun MS or high-performance liquid chromatography-MS. The lipid class separation is performed b...

متن کامل

Global analysis of the yeast lipidome by quantitative shotgun mass spectrometry.

Although the transcriptome, proteome, and interactome of several eukaryotic model organisms have been described in detail, lipidomes remain relatively uncharacterized. Using Saccharomyces cerevisiae as an example, we demonstrate that automated shotgun lipidomics analysis enabled lipidome-wide absolute quantification of individual molecular lipid species by streamlined processing of a single sam...

متن کامل

Flexibility of a Eukaryotic Lipidome – Insights from Yeast Lipidomics

Mass spectrometry-based shotgun lipidomics has enabled the quantitative and comprehensive assessment of cellular lipid compositions. The yeast Saccharomyces cerevisiae has proven to be a particularly valuable experimental system for studying lipid-related cellular processes. Here, by applying our shotgun lipidomics platform, we investigated the influence of a variety of commonly used growth con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 116  شماره 

صفحات  -

تاریخ انتشار 2014