Plasma glucose levels throughout the day and HbA(1c) interrelationships in type 2 diabetes: implications for treatment and monitoring of metabolic control.

نویسندگان

  • E Bonora
  • F Calcaterra
  • S Lombardi
  • N Bonfante
  • G Formentini
  • R C Bonadonna
  • M Muggeo
چکیده

OBJECTIVE To evaluate the extent of plasma glucose excursions with meals, the relations between plasma glucose levels at different times of the day, and the relations between the latter and HbA(1c) in non-insulin-treated type 2 diabetic subjects. RESEARCH DESIGN AND METHODS Daily glucose profiles were assessed in non-insulin-treated type 2 diabetic patients. Outpatients at the diabetes clinic (n = 371; one daily plasma glucose profile) and at home (n = 30; five daily blood glucose profiles over 1 month) as well as inpatients (n = 455; profile of plasma glucose on the day of admission) were examined. Subjects had plasma/blood glucose assessment before and 2-3 h after breakfast, lunch, and dinner. HbA(1c) was also measured. RESULTS After the meals many subjects had glucose levels >8.9 mmol/l (160 mg/dl) and/or glucose excursions >2.2 mmol/l (40 mg/dl). This was also often found when HbA(1c) was satisfactory (<7%). The coefficients of simple correlation among plasma/blood glucose at different times of the day ranged from 0.52 to 0.88. Correlations between HbA(1c) and plasma/blood glucose at different times of the day ranged from 0.44 to 0.67. The strongest correlation was between HbA(1c) and mean daily glucose (r = 0.57-0.69). Multiple regression analyses showed that premeal but not postmeal plasma/blood glucose levels were independent predictors of HbA(1c). CONCLUSIONS These results suggest that 1) the majority of non-insulin-treated type 2 diabetic patients have exaggerated plasma/blood glucose excursions with meals, and many of them have higher-than-recommended glucose concentrations 2 h after the meals; 2) plasma/blood glucose levels throughout the day are not as strongly interrelated as one might believe; and 3) HbA(1c) is more related to preprandial than postprandial plasma/blood glucose levels. These findings have potential implications for treatment and monitoring of metabolic control in type 2 diabetes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The glucose area under the profiles obtained with continuous glucose monitoring system relationships with HbA(lc) in pediatric type 1 diabetic patients.

OBJECTIVE The purpose of this study was to determine whether the continuous glucose monitoring system (CGMS) (MiniMed, Sylmar, CA) 1) is sufficiently representative of the overall metabolic control as assessed by HbA(1c), 2) could be used to identify a particular blood glucose threshold value affecting hemoglobin glycation; and 3) is able to show any relationship between particular glycemic pro...

متن کامل

The association between serum lipids profile and HbA1c in type 2 diabetes mellitus in Tehran, Iran

Background and aims: Dyslipidemia is one of the major factors implicated in the development of the vascular complications of diabetes. In this study, it was evaluated the association between serum lipids profile and Hemoglobin A1c (HbA1c) in type 2 diabetes mellitus. Methods: In this cross-sectional study, the serum lipid profile and...

متن کامل

Does Glucose Variability Influence the Relationship Between Mean Plasma Glucose and HbA1c Levels in Type 1 and Type 2 Diabetic Patients?

OBJECTIVE The A1C-Derived Average Glucose (ADAG) study demonstrated a linear relationship between HbA(1c) and mean plasma glucose (MPG). As glucose variability (GV) may contribute to glycation, we examined the association of several glucose variability indices and the MPG-HbA(1c) relationship. RESEARCH DESIGN AND METHODS Analyses included 268 patients with type 1 diabetes and 159 with type 2 ...

متن کامل

Defining the relationship between plasma glucose and HbA(1c): analysis of glucose profiles and HbA(1c) in the Diabetes Control and Complications Trial.

OBJECTIVE To define the relationship between HbA(1c) and plasma glucose (PG) levels in patients with type 1 diabetes using data from the Diabetes Control and Complications Trial (DCCT). RESEARCH DESIGN AND METHODS The DCCT was a multicenter, randomized clinical trial designed to compare intensive and conventional therapies and their relative effects on the development and progression of diabe...

متن کامل

Performance characteristics and clinical utility of an enzymatic method for the measurement of glycated albumin in plasma.

OBJECTIVE The measurement of plasma glycated albumin is particularly useful in the short-middle term monitoring of glycometabolic control in diabetics. The aim of this work is to evaluate a new enzymatic method for the measurement of glycated albumin in plasma, with particular attention to some selected cases and comparison with other relevant tests (fasting plasma glucose, after glucose load, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes care

دوره 24 12  شماره 

صفحات  -

تاریخ انتشار 2001