Indirect kinetic spectrophotometric determination of hydroxylamine based on its reaction with iodate.
نویسندگان
چکیده
A simple, precise and accurate method is proposed for rapid determination of trace amounts of hydroxylamine based on the reaction of hydroxylamine with iodate in acidic media. The reaction of neutral red by the produced nitrite ion was used to monitor the reaction spectrophotometrically at 525 nm by a fixed time method. Hydroxylamine in the range of 0.0400-1.200 microg mL(-1) could be determined. The relative standard deviation for 10 determinations of 0.500 microg mL(-1) hydroxylamine was 1.81% and the limit of detection was 0.010 microg mL(-1). The proposed method was applied to the determination of hydroxylamine in water samples with satisfactory results.
منابع مشابه
Spectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run
A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...
متن کاملKinetic-Spectrophotometric Determination of Track Amounts of Nitrite Ion Based on Its Reduction Reaction with Thionine in Acidic Media
A simple, sensitive and rapid method for determination of trace amounts of nitrite ion in real samples is reported. The reaction is initiated by adding known volumes of a nitrite ion solution of identified concentration to acidic solutions of thionine which causes decolorizaiton of reagent with time. The absorbance changes is then monitored spectrophotometrically at l...
متن کاملKinetic-Spectrophotometric Determination of Thiocyanate Based on Its Inhibitory Effect on the Oxidation of Pyrogallol Red by Bromate
A kinetic spectrophotometric method for rapid measurement of thiocyanate in serum, urine and sewage water with no need for removed of interfering substances in described. The method is based on the inhibitory effect of thiocyanate on the oxidation of pyrogallol red by bromated and nitrite which is monitored at 467 nm. The variables affecting the rate of the reaction were investigated and th...
متن کاملSensitive kinetic-spectrophotometric determination of iodate in iodized table salt based on its accelerating effect on the reaction of bromate with chloride ion in the presence of hydrazine.
A simple, precise, sensitive and accurate method was developed for rapid determination of trace quantities of iodate. The method is based on the accelerating effect of iodate on the reaction of bromate and chloride acid in the presence of hydrazine in acidic media. The decolorization of Methyl Orange with the reaction products was used to monitor the reaction spectrophotometrically at 525 nm. I...
متن کاملCatalytic Kinetic Determination of Silver through its Catalytic Effect on Congo Red-Peroxodisulphate Reaction
A kinetic-spectrophotometric procedure is reported for determination of trace amounts of Ag(I). This method is based on catalytic effect of silver ion on the oxidation of congo red by potassium peroxodisulphate at pH=3.4 and 30 oC in the presence of 1,10-phenanthroline as an activator. The reaction was followed spectrophotometrically by measuring the rate of change in absorbance ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 2 شماره
صفحات -
تاریخ انتشار 2006