Cross-calibration of the Siemens mMR: easily acquired accurate PET phantom measurements, long-term stability and reproducibility
نویسندگان
چکیده
BACKGROUND We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens Biograph mMR PET/MR system. We perform regular cross-calibrations (Xcal) of our PET systems, including the PET/MR, using a Siemens mCT water phantom. LONG-TERM STABILITY The mMR calibration stability was evaluated over a 3-year period where 54 cross-calibrations were acquired, showing that the mMR on average underestimated the concentration by 16 %, consistently due to the use of MR-based μ-maps. The mMR produced the narrowest calibration ratio range with the lowest standard deviation, implying it is the most stable of the six systems in the study over a 3-year period. MMR ACCURACY WITH PREDEFINED μ-MAPS: With the latest mMR software version, VB20P, it is possible to utilize predefined phantom μ-maps. We evaluated both the system-integrated, predefined μ-map of the long mMR water phantom and our own user-defined CT-based μ-map of the mCT water phantom, which is used for cross-calibration. For seven scans, which were reconstructed with correctly segmented μ-maps, the mMR produced cross-calibration ratios of 1.00-1.02, well within the acceptance range [0.95-1.05], showing high accuracy. CONCLUSIONS The mMR is the most stable PET system in this study, and the mean underestimation is no longer an issue with the easily accessible μ-map, which resulted in correct cross-calibration ratios in all seven tests. We will share the user-defined μ-map of the mCT phantom and the protocol with interested mMR users.
منابع مشابه
Validation of a simultaneous PET/MR system model for PET simulation using GATE
LaTIM UMR 1101, Brest, France Simultaneous PET/MR acquisition shows promise in a range of applications. Simulation using GATE is an essential tool that allows obtaining the ground truth for such acquisitions and therefore helping in the development and the validation of innovative processing methods such as PET image reconstruction, attenuation correction and motion correction. The purpose of t...
متن کاملNEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging
BACKGROUND In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements...
متن کاملThe physical characteristics of a SLIC-EPID for transmitted dosimetry
ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملStability Study of Measles AIK-C Strain, Mumps RS-12 Strain and Rubella Takahashi Strain in MMR Vaccine
Stability studies play a critical role in assuring product quality at all points in the vaccine life cycle and havea major impact on the success of immunization programs worldwide. The purpose of stability study isdetermination of the vaccine quality under the variety of environmental factors and to establish a re-testperiod or a shelf life and recommended storage conditions. In this study thre...
متن کامل