Application of Pyridine-2-carbaldehyde-2-(4-methyl-1,3-benzo thiazol-2-yl)hydrazone as a Neutral Ionophore in the Construction of a Novel Er(III) Sensor

نویسندگان

  • Mohammad Reza Ganjali
  • Morteza Rezapour
  • Solmaz Rasoolipour
  • Parviz Norouzi
  • Mehdi Adib
چکیده

A piridina-2-carbaldeído-2-(4-metil-1,3-benzotiazol-2-il) hidrazona (PCMHT) pode ser usada como um ionóforo neutro apropriado à preparação de uma membrana sensora a Er(III), com alta seletividade. A composição ótima encontrada foi PCMHT-PVC-KTpClPB-BA com as razões de 6,0:30,0:5,0:59,0, respectivamente. A resposta Nernstiniana foi de 21,8 ± 0,5 mV década para a atividade de Er(III). O intervalo linear encontrado para o sensor foi relativamente grande (de 1,0×10 a 1,0 ×10 mol L). Sua funcionalidade no intervalo de pH entre 2,5 e 12,0 o torna adequado para aplicações analíticas. O limite de detecção mais baixo do sensor foi 5,0 ×10 mol L. A excelente seletividade a Er(III) do sensor proposto, frente aos íons metálicos mais comuns e, especialmente íons lantanídeos, é uma outra vantagem. O sensor foi usado com sucesso como eletrodo indicador na titulação de 25 mL de 1,0 × 10 mol L de íons Er(III) com 1,0 × 10 mol L de EDTA. O sensor proposto foi usado na monitoração direta de Er(III) em misturas binárias e na determinação indireta de íons fluoreto em duas preparações de enxágüe bucal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metabotropic glutamate receptor 5 antagonist protects dopaminergic and noradrenergic neurons from degeneration in MPTP-treated monkeys.

Degeneration of the dopaminergic nigrostriatal system and of noradrenergic neurons in the locus coeruleus are important pathological features of Parkinson's disease. There is an urgent need to develop therapies that slow down the progression of neurodegeneration in Parkinson's disease. In the present study, we tested whether the highly specific metabotropic glutamate receptor 5 antagonist, 3-[(...

متن کامل

Preparation and Application of Al3+ - Sensor Based On (2Z) — Methyl 2 — ((z) (p-tolylimino) -3-Ethyl —4-0xothiazolidin —5— Ylidene Acetate in PVC Matrix

Al3+-Potentiometric sensor, based on (2Z) -methyl 2- ((z) (p-tolylimino)-3-ethyl -4-oxothiazolidin -5- ylidene) Acetate (MTEOY) as a neutral ionophore, was successfully developed for the detectionof Al3+ in aqueous solutions. The electrode responds to Al3+ ion with a sensitivity of 19.8 ± 0.1 mV/decade over the range 1.0 x 10-8- 1.0 x 10-1 mol LT' and in a pH range of 3.0-9.0. The electrodeshow...

متن کامل

Unusual product distribution from Friedländer reaction of di- and triacetylbenzenes with 3-aminonaphthalene-3-carbaldehyde and properties of new benzo[g]quinoline-derived aza-aromatics.

The Friedländer reactions of acetylbenzenes and 2-acetylpyridine with 3-aminonaphthalene-2-carbaldehyde afforded the corresponding 2-phenylbenzo[g]quinoline and 2-(pyrid-2-yl)benzo[g]quinoline, respectively. The same reactions of 3-aminonaphthalene-2-carbaldehyde with 1,2-, 1,3-, 1,4-di- and 1,3,5-triacetylbenzenes, however, afforded a series of corresponding (benzo[g]quinolin-2-yl)benzenes as ...

متن کامل

A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...

متن کامل

A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples

A new polyvinyl choloride (PVC) membrane sensor for cerium(III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensorexhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with aNernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two month...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007