Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T.

نویسندگان

  • Richard Keith Downs
  • Mariah Haider Bashir
  • Chin Kau Ng
  • Jens Olaf Heidenreich
چکیده

INTRODUCTION Creating contrast between normal anatomy and pathology is the main goal of imaging. Here we compare contrast ratios of enhancing brain lesions at 1.5T between T1 TSE, magnetization prepared rapid gradient echo (MPRAGE) and subtraction and at 3T between T1 FLAIR, MPRAGE and subtraction. METHODS Contrast ratio between enhancing lesions and normal contralateral brain was measured for above mentioned sequences during the same imaging session. A total of 27 exams on 25 patients were evaluated. RESULTS A total of 90 enhancing brain lesions were utilized. Of these 46 were <5 mm diameter. Taking all lesions into account there was a small but statistically significant improvement in contrast ratio at 1.5T with MPRAGE compared to T1 TSE and at 3T for T1 FLAIR compared to MPRAGE. However, there was no statistically significant difference between these sequences for lesions 5 mm or less in diameter. However, subtraction provided a marked and statistically significant improvement in contrast ratio for both all lesions and including only lesions 5 mm or less in diameter. CONCLUSIONS Our data indicate that for small lesions at 1.5T there is no significant difference in contrast ratio (CR) between T1 TSE and MPRAGE or at 3T between T1 FLAIR and MPRAGE despite the MPRAGE having the advantage of much thinner slices and a higher matrix. However, subtraction provided a markedly improved CR for all lesions at 1.5T and 3T regardless of lesion size. Subtraction should be considered for clinical use to improve detection of small or subtle enhancing lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of MR lymphangiography with a G6 macromolecular contrast agent obtained at 1.5T and 3.0T Systems

Y. Hama, M. Bernardo, Y. Koyama, C. A. Regino, M. W. Brechbiel, P. L. Choyke, H. Kobayashi Molecular Imaging Program, NCI/NIH, Bethesda, Maryland, United States, Molecular Imaging Program, SAIC-Frederick, NCI/NIH, Bethesda, Maryland, United States, Radiation Oncology Branch, NCI/NIH, Bethesda, Maryland, United States Introduction Higher field strength magnets are theoretically superior in signa...

متن کامل

Continuously Moving Table Mr Imaging at 3t: a Comparison to 1.5t

INTRODUCTION In the last years, continuously moving table (CMT) acquisition techniques have been developed to efficiently acquire extended Fields of View (FoV). Clinical relevance of these techniques, especially for cancer patients, has been reported [1-3] and CMT acquisitions are used in our daily clinical routine for metastases screening at 1.5T. However, 3T scanners are getting more and more...

متن کامل

Comparison of the added value of contrast-enhanced 3D fluid-attenuated inversion recovery and magnetization-prepared rapid acquisition of gradient echo sequences in relation to conventional postcontrast T1-weighted images for the evaluation of leptomeningeal diseases at 3T.

BACKGROUND AND PURPOSE The usefulness of contrast-enhanced 3D T2-FLAIR MR imaging for the evaluation of leptomeningeal diseases has not been systematically investigated. The purpose of this study was to assess the value added by contrast-enhanced 3D T2-FLAIR and MPRAGE sequences to conventional postcontrast T1-weighted images in the evaluation of leptomeningeal diseases. We also undertook in vi...

متن کامل

Normal findings on brain fluid-attenuated inversion recovery MR images at 3T.

BACKGROUND AND PURPOSE Fluid attenuated inversion recovery (FLAIR) MR imaging of the brain has become a routine tool for assessing lesions in patients with suspected neurologic disorders. There is growing interest in 3T brain FLAIR MR imaging but little normative data are available. The purpose of this study was to evaluate the frequency and topography of cerebral hyperintensities seen with FLA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Quantitative imaging in medicine and surgery

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 2013