Simultaneous liquid-chromatographic determination of vitamin K1 and vitamin E in serum.

نویسندگان

  • B E Cham
  • H P Roeser
  • T W Kamst
چکیده

We describe a high-performance liquid chromatographic procedure for the simultaneous measurement of vitamins K1 and E in human serum. Delipidated human serum (free of vitamins K1 and E) was used to make standard solutions of these vitamins, and cetyl naphthoate and alpha-tocopheryl acetate were the internal standards for vitamin K1 and vitamin E, respectively. A simple, novel separation method utilizing liquid-liquid partition chromatography was used as a preparative "clean-up" procedure. Cetyl naphthoate and vitamin K1 (after post-column reduction) were detected by fluorescence, alpha-tocopheryl acetate and vitamin E by ultraviolet absorption. Sensitivity (detection limit) of the assay was 30 pg for vitamin K1 and 5 ng for vitamin E per injection. The method is specific, precise, and more rapid than previously described procedures. Within- and between-assay CVs were 8.1% and 12.9%, respectively, for vitamin K1; 3.5% and 6.0%, respectively, for vitamin E. Analytical recoveries of vitamins K1 and E were 80% and 93%, respectively, from serum and from delipidated serum (standards). The average neonatal serum concentration of vitamin K1 was 83 ng/L, 2.5 mg/L for vitamin E; for normolipidemic adults, the values were 343 ng/L and 7.9 mg/L, respectively, and for hyperlipidemic adults, 541 ng/L and 11.1 mg/L, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid-chromatographic determination of vitamin K1 in plasma, with fluorometric detection.

This assay for phylloquinone (vitamin K1) in plasma requires a single liquid-chromatographic step. Much smaller volumes of plasma (0.5-1.0 mL) are required than in previous assays. Before liquid chromatography, we purified crude lipid extracts by conventional chromatography on silica, then extracted the lipid fraction by dissolving it in an acidic mixture of hexane/acetonitrile (1/4 by vol) con...

متن کامل

Determination of vitamin K1 in medical foods by liquid chromatography with postcolumn reduction and fluorometric detection.

A liquid chromatographic (LC) method is described for the determination of vitamin K1 in medical foods. The sample is enzymatically digested with lipase and alpha-amylase and extracted with 1% sodium bicarbonate solution-isopropanol (1 + 1). After C18 solid-phase extraction, vitamin K1 is separated by nonaqueous reversed-phase LC, converted to the hydroquinone by postcolumn zinc reduction, and ...

متن کامل

Adsorptive Stripping Voltammetry in Lipophilic Vitamins Determination

The aim of this contribution was to check if adsorptive stripping differential pulse voltammetry (AdSDPV) is suitable tool for sensitive simultenous electrochemical detection of lipophilic vitamins. Retinol (vitamin A1), cholecalciferol (vitamin D3), α-tocopherol (vitamin E) and phylloquinone (vitamin K1) were selected as representatives. All electrochemical measurements were performed in two s...

متن کامل

Simultaneous determination of retinol and α-tocopherol by high pressure liquid chromatography in micro-volumes of serum.

The lack of biochemical data to indicate the prevalence of marginal vitamin A deficiency (VAD) in the country is largely because of the difficulty of obtaining enough serum for analysis, especially from malnourished children. Efforts were therefore made to establish a high-pressure liquid chromatography system (HPLC) for the determination of retinol in micro-volumes of serum. Since our previous...

متن کامل

Analysis of supplemented vitamin K1(20) in serum microsamples by solid-phase extraction and narrow-bone HPLC with multichannel ultraviolet detection.

A sensitive method for the determination of vitamin K1(20) in serum microsamples (50 microL) has been developed, utilizing solid-phase extraction with C8 Bond-Elut columns and reversed-phase narrow-bore high-performance liquid chromatography [2.1 mm (i.d.), column] with a nonaqueous eluent. Recovery from serum (49 ng/mL) was 76% (n = 2). Peak homogeneity was assessed by photodiode array detecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 1989