Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate?

نویسندگان

  • Woo-Bin Jung
  • Eun-Sun Moon
  • Sung-Kyu Kim
  • David Kovacevic
  • Myung-Sun Kim
چکیده

BACKGROUND The purpose of this study was to evaluate the role of medial support and clinical factors responsible on outcomes and major complications associated with treatment of unstable proximal humerus fractures using a locking plate and suture augmentation. METHODS Sixty-three cases in 62 patients (42 female, 20 male) were evaluated between September 2004 and October 2008. Cases were divided into either a medial support group (36 cases) or non-medial support group (27 cases). Clinical and radiographic evaluations included Neer's evaluation criteria, the neck-shaft angle using the Paavolainen method, and complications. We analyzed the correlation between bone- and fracture- related complications and three independent clinical variables, such as the presence of medial support, fracture type, and osteoporosis by way of multivariate logistic regression. RESULTS There were statistically significant differences in the overall incidence of complications based on the presence of medial support (p = 0.014) and preoperative fracture type (p = 0.018), but no differences based on the presence of osteoporosis (p = 0.157). According to multivariate logistic regression analysis, the restoration of medial support was the most reliable factor to prevent bone- and fracture- related complications. In addition, when we compared the incidence of bone- and fracture-related complications in the presence or absence of medial support among 30 patients with osteoporosis, the group with restoration of medial support had only one complication of humeral head osteonecrosis despite the presence of osteoporosis (5.9% vs. 46.2%, p = 0.025). According to Neer's criteria, excellent or satisfactory clinical results accounted for seventy-three percent of the total cases (46 of 63 cases). Seventy-eight percent (49 of 55 cases) showed good radiographic results by the Paavolainen method. There were 14 complications in 13 of 63 cases (20.6%). CONCLUSIONS In the treatment of unstable proximal humerus fractures with locking plate technology and suture augmentation, we suggest that obtaining medial support is an important factor in preventing major bone- and fracture-related postoperative complications such as reduction loss or nonunion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

BACKGROUND Comminuted fractures of the proximal humerus are generally treated with the locking plate system, and clinical results are satisfactory. However, unstable support of the medial column results in varus malunion and screw perforation. We designed a novel medial anatomical locking plate (MLP) to directly support the medial column. Theoretically, the combined application of locking plate...

متن کامل

Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...

متن کامل

The Mechanical Benefit of Medial Support Screws in Locking Plating of Proximal Humerus Fractures

BACKGROUND The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs) in the locking proximal humeral plate for treating proximal humerus fractures. METHODS Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal hume...

متن کامل

Application of Additional Medial Plate in Treatment of Proximal Humeral Fractures With Unstable Medial Column

The purpose of this study was to use finite element analysis to compare the biomechanical characteristics after lateral locking plate (LLP) or LLP with a medial anatomical locking plate (LLP-MLP) fixation of proximal humeral fractures with an unstable medial column.First, a 3-dimensional, finite element analysis model was developed. Next, LLP and LLP-MLP implants were instrumented into the prox...

متن کامل

Locking plate fixation for proximal humerus fractures.

Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013