Importance of Gradients in Membrane Properties and Electrical Coupling in Sinoatrial Node Pacing

نویسندگان

  • Shin Inada
  • Henggui Zhang
  • James O. Tellez
  • Nitaro Shibata
  • Kazuo Nakazawa
  • Kaichiro Kamiya
  • Itsuo Kodama
  • Kazuyuki Mitsui
  • Halina Dobrzynski
  • Mark R. Boyett
  • Haruo Honjo
چکیده

The sinoatrial node (SAN) is heterogeneous in terms of cell size, ion channels, current densities, connexins and electrical coupling. For example, Nav1.5 (responsible for INa) and Cx43 (responsible for electrical coupling) are absent from the centre of the SAN (normally the leading pacemaker site), but present in the periphery (at SAN-atrial muscle junction). To test whether the heterogeneity is important for the functioning of the SAN, one- and two-dimensional models of the SAN and surrounding atrial muscle were created. Normal functioning of the SAN (in terms of cycle length, position of leading pacemaker site, conduction times, activation and repolarization sequences and space constants) was observed when, from the centre to the periphery, (i) cell characteristics (cell size and ionic current densities) were changed in a gradient fashion from a central-type (lacking INa) to a peripheral-type (possessing INa) and (ii) coupling conductance was increased in a gradient fashion. We conclude that the heterogeneous nature of the node is important for its normal functioning. The presence of Nav1.5 and Cx43 in the periphery may be essential for the node to be able to drive the atrial muscle: Nav1.5 provides the necessary depolarizing current and Cx43 delivers it to the atrial muscle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.

Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...

متن کامل

Mechanism of Discordant Alternans in Spatially Homogeneous Tissue

abstract Discordant alternans, the phenomenon of separate cardiac tissue locations exhibiting action potential duration (APD) alternans of opposite phase, appears to be a potential mechanism for electrocardiographic T wave alternans, but its initiation mechanism is unknown. We studied behavior of one-and two-dimensional cardiac tissue spatially homogeneous in all respects, including APD restitu...

متن کامل

Complete Atrial-Specific Knockout of Sodium-Calcium Exchange Eliminates Sinoatrial Node Pacemaker Activity

The origin of sinoatrial node (SAN) pacemaker activity in the heart is controversial. The leading candidates are diastolic depolarization by "funny" current (If) through HCN4 channels (the "Membrane Clock" hypothesis), depolarization by cardiac Na-Ca exchange (NCX1) in response to intracellular Ca cycling (the "Calcium Clock" hypothesis), and a combination of the two ("Coupled Clock"). To addre...

متن کامل

Improvement of Coverage Algorithm in WSN in Terms of Sensor Numbers and Power Amount

Wireless sensor networks(WSN) have unique properties that distinguished them from other wireless networks and have special challenges. Not-chargeable, not-changeable and limited power supplies of sensor nodes is the most important challenge of this networks, and if the power supply of node expired, a part of data maybe lost. Because of the importance of covers in wireless sensors, in this work ...

متن کامل

Comparison of Hyperpolarization-Activiated Current “if ” on the Rate of Spontaneous Activity and Cycle Length before and after Cutting of Atrial Muscle away from Intact Sinoatrial Node of Rabbit

It has been shown that the hyperpolarization-activated current “if” that is blocked by 2 mM Cs+ plays a minor role on pacemaker activity of the center and a major role on activity of the periphery of rabbit intact sino-atrial node. On the other hand some investigations showed that if the atrial muscle, surrounding the sino-atrial node, is cut away there is a shift in leading pacemaker site from...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014