Spurious hyperglycaemia--a hazard of finger prick blood glucose estimation.

نویسندگان

  • E McInnes
  • H Cohen
چکیده

Two diabetic patients presented in coma to the accident and emergency department. Although they were hypoglycaemic, the initial blood glucose reagent strip readings were high. We postulate that glucose contamination of their fingers occurred and resulted in spuriously high readings. A small survey highlights the problems resulting from such contamination. Correct handling of blood glucose reagent strips is stressed and we advise venous blood samples in all diabetic emergencies presenting to the accident and emergency department.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predonation finger lancet punctures: a potential risk factor for interdonor pathogen transmission in the blood donor clinic.

BACKGROUND AND OBJECTIVES Point-of-care testing using capillary blood from a finger prick is widely used for predonation haemoglobin testing of blood donors. It is common practice to cover the finger prick with a cotton swab and to instruct the donor to press for few minutes. The finger prick can cause blood contamination of surfaces in contact with the lanced finger, especially door handles, r...

متن کامل

Forearm blood glucose testing in diabetes mellitus.

AIMS To compare the accuracy and acceptability of capillary blood glucose testing from the forearm with finger prick testing in diabetic children. METHODS Blood glucose measurements from samples taken from the forearm and the finger were compared in an outpatient setting from 52 children and adolescents with diabetes mellitus aged 6-17 years. Opinions on forearm sampling were collected by que...

متن کامل

Noninvasive Technique for Estimating Blood Glucose Levels among Diabetic Patients.

AIM The present study was aimed to assess the fasting and postprandial gingival crevicular blood (GCB) glucose and finger stick blood glucose measurements using a glucometer. MATERIALS AND METHODS A total of 30 subjects with periodontitis and positive bleeding on probing were considered. Subjects were instructed to report to the department after overnight fasting. Gingival crevicular blood sa...

متن کامل

Screening for diabetes mellitus using gingival crevicular blood with the help of a self-monitoring device

PURPOSE The purpose of study was to compare blood glucose in capillary finger-prick blood and gingival crevice blood using a self-monitoring blood glucose device among patients with gingivitis or periodontitis. METHODS Thirty patients with gingivitis or periodontitis and bleeding on probing (BOP) were chosen. The following clinical periodontal parameters were noted: probing depth, BOP, gingiv...

متن کامل

Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes.

OBJECTIVE The purpose of this study was to characterize the distribution of the rate of change of blood glucose for a diabetic population. RESEARCH DESIGN AND METHODS The study population consisted of 124 adults with type 1 or type 2 diabetes requiring insulin. Study participants applied a GlucoWatch Biographer during the day at home for 5 consecutive days and took finger-prick blood glucose ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of emergency medicine

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 1984