Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty.

نویسندگان

  • Robert A Siston
  • Melinda J Cromie
  • Garry E Gold
  • Stuart B Goodman
  • Scott L Delp
  • William J Maloney
  • Nicholas J Giori
چکیده

BACKGROUND Computer navigation systems generally establish the rotational alignment axis of the femoral component on the basis of user-defined anatomic landmarks. However, navigation systems can also record knee kinematics and average alignment axes established with multiple techniques. We hypothesized that establishing femoral rotational alignment with the use of kinematic techniques is more accurate and precise (repeatable) than the use of anatomic techniques and that establishing femoral rotational alignment by averaging the results of different alignment techniques is more accurate and precise than the use of a single technique. METHODS Twelve orthopaedic surgeons used three anatomic and two kinematic alignment techniques to establish femoral rotational alignment axes in a series of nine cadaver knees. The axes derived with the individual anatomic and kinematic techniques as well as the axes derived with six combination techniques--i.e., those involving averaging of the alignments established with two of the individual techniques--were compared against a reference axis established with computed tomography images of each femur. RESULTS The kinematic methods were not more accurate (did not have smaller mean errors) or more precise (repeatable) than the anatomic techniques. The combination techniques were accurate (five of the six had a mean error of <5 degrees ) and significantly more precise than all but one of the single methods. The percentage of measurements with <5 degrees of error as compared with the reference epicondylar axis was 37% for the individual anatomic techniques, 30% for the individual kinematic techniques, and 58% for the combination techniques. CONCLUSIONS Averaging the results of kinematic and anatomic techniques, which is possible with computer navigation systems, appears to improve the accuracy of rotational alignment of the femoral component. The number of rotational alignment outliers was reduced when combination techniques were used; however, they are still a problem and continued improvement in methods to accurately establish rotation of the femoral component in total knee arthroplasty is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

The variability of femoral rotational alignment in total knee arthroplasty.

BACKGROUND Several reference axes are used to establish femoral rotational alignment during total knee arthroplasty, but debate continues with regard to which axis is most accurately and easily identified during surgery. Computer-assisted navigation systems have been developed in an attempt to more accurately and consistently align implants during total knee arthroplasty, but it is unknown if n...

متن کامل

Aging Effect on Femoral Stress Fracture Risk after Computer-navigated Total Knee Arthroplasty

INTRODUCTION Recent clinical studies have shown that computer navigation for total knee arthroplasty (TKA) provides improved component alignment accuracy, and can help to avoid femoral malrotation and errors in axial alignment [1]. However, femoral stress fracture after computernavigated TKA has been reported due to the pin hole [2] and we hypothesized that osteoporosis would be one of the key ...

متن کامل

Inaccurate rotational component position in image-free navigated unicompartmental knee arthroplasty

Background/Objective The success of unicompartmental knee arthroplasty (UKA) is highly dependent on the accuracy of component and leg alignment. Computer-assisted surgery is gaining popularity in total knee arthroplasty with numerous studies reporting improved accuracy and decreased variability in implant position and postoperative limb alignment compared with conventional techniques. However, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 90 10  شماره 

صفحات  -

تاریخ انتشار 2008