Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging
نویسنده
چکیده
The paper presents the multi-element synthetic transmit aperture (MSTA) method with a small number of elements transmitting and all elements apertures in medical ultrasound imaging. As compared to the other methods MSTA allows to increase the system frame rate and provides the best compromise between penetration depth and lateral resolution. In the experiments a 128-element linear transducer array with 0.3 mm pitch excited by a burst pulse of 125 ns duration were used. The comparison of 2D ultrasound images of tissue mimicking phantom obtained using the STA and the MSTA methods is presented to demonstrate the benefits of the second approach. The results were obtained using SA algorithm with transmit and receive signals correction based on a single element directivity function. Keywords—Beamforming, frame rate, synthetic aperture, ultrasound imaging
منابع مشابه
Transmit Sub-aperture Optimization in MSTA Ultrasound Imaging Method
The paper presents the optimization problem for the multi-element synthetic transmit aperture method (MSTA) in ultrasound imaging applications. The optimal choice of the transmit aperture size is performed as a trade-off between the lateral resolution, penetration depth and the frame rate. Results of the analysis obtained by a developed optimization algorithm are presented. Maximum penetration ...
متن کاملCoded Transmission in Synthetic Transmit Aperture Ultrasound Imaging Method
The paper presents the study of synthetic transmit aperture method applying the Golay coded transmission for medical ultrasound imaging. Longer coded excitation allows to increase the total energy of the transmitted signal without increasing the peak pressure. Signal-to-noise ratio and penetration depth are improved maintaining high ultrasound image resolution. In the work the 128-element linea...
متن کاملIn Vitro Study of Coded Transmission in Synthetic Aperture Ultrasound Imaging Systems
In the paper the study of synthetic transmit aperture method applying the Golay coded transmission for medical ultrasound imaging is presented. Longer coded excitation allows to increase the total energy of the transmitted signal without increasing the peak pressure. Moreover signal-to-noise ratio and penetration depth are improved while maintaining high ultrasound image resolution. In the work...
متن کاملSynthetic Transmit Aperture Method in Medical Ultrasonic Imaging
The work describes the use of a synthetic transmit aperture (STA) with a single element transmitting and all elements receiving in medical ultrasound imaging. STA technique is a novel approach to today’s commercial systems, where an image is acquired sequentially one image line at a time that puts a strict limit on the frame rate and the amount of data needed for high image quality. The STA ima...
متن کاملImage formation and restoration using multi-element synthetic array processing
Traditionally, the number of transmit and receive processing channels is equal to the number of transducers (N) in an ultrasound imaging system. Certain applications limit the number of processing channels such that there are fewer channels than transducer elements. For these cases, a subset of M adjacent transducers—a multi-element subarray— performs echo transmission and reception. The proces...
متن کامل