Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inversion recovery T1-weighted MRI

نویسندگان

  • Nahideh Gharehaghaji
  • Mahmood Nazarpoor
  • Hodaiseh Saharkhiz
چکیده

BACKGROUND Ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles are used as blood pool contrast agent for magnetic resonance angiography and perfusion imaging. Our aim in this study was to investigate the effect of the two coating types of iron oxide nanoparticles on the relationship between nanoparticles concentration and signal intensity (SI) in T1-weighted MR images. METHODS Different concentrations of the polyethylene glycol (PEG), and carboxydextran-coated iron oxide nanoparticles were imaged using inversion recovery Turbo-FLASH (Turbo fast low-angle shot) pulse sequence with inversion times (TIs) of 300-900 ms (interval of 100 ms). The maximum non-linear and linear relationship between the corrected SI (after non-uniformity correction) and the concentration of the two coated nanoparticles were calculated in T1-weighted images. RESULTS The maximum non-linear relationship between the corrected SI and the concentration of the PEG, and carboxydextran-coated nanoparticles were obtained at concentrations of 400 and 200 μmol Fe/L at a TI of 900 ms, respectively. In addition, the maximum linear relationship between the corrected SI and the concentration of the PEG, and carboxydextran-coated nanoparticles (R2=0.99) appeared at 228.184 and 205.654 μmolFe/L with a TI of 300 ms, respectively. CONCLUSION The maximum non-linear corrected SI of the carboxydextran-coated nanoparticles was slightly higher than that of the PEG-coated nanoparticles at similar TIs. However, the PEG-coated nanoparticles were better than the carboxydextran-coated nanoparticles as a T1 contrast agent for perfusion measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inver-sion recovery T1-weighted MRI

  Background: Ultrasmallsuperparamagnetic iron oxide (USPIO) nanoparticles are used as blood pool contrast agent for magnetic resonance angiography and perfusion imaging. Our aim in this study was to investigate the effect of the two coating types of iron oxide nanoparticles on the relationship between nanoparticles concentration and signal intensity (SI) in T1-weighted MR images.   Methods : D...

متن کامل

اثر زمان معکوس بر ارتباط خطی بین غلظت نانوذرات اکسید آهن با پوشش پلی اتیلن گلیکول و شدت سیگنال در تصویربرداری تشدید مغناطیسی با سکانس بازیافت معکوس

Background and purpose: In MRI the concentration of contrast agent is indirectly measured from signal intensity (SI). It is important to find the maximum linear relationship between SI and concentration of the iron oxide nanoparticles for perfusion measurement. The aim of this study was to investigate the effect of inversion time on SI and the maximum linear relationship between SI and concentr...

متن کامل

Potential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times

Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...

متن کامل

Effect of Flip Angle on the Correlation Between Signal Intensity and Different Concentrations of Iron Oxide Nanoparticles Using T1-Weighted Turbo-FLASH Inversion Recovery Sequence

BACKGROUND Ultrasmall superparamagnetic iron oxide nanoparticles have been used as a blood pool contrast agent for magnetic resonance angiography and perfusion studies. Linear relationship between signal intensity (SI) and nanoparticle concentration is essential for perfusion measurement. OBJECTIVES The aim of this study was to investigate the effect of different flip angles on maximum SI and...

متن کامل

Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence

Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015