Evaluation of a rapid immunochromatographic ODK0501 assay for detecting Streptococcus pneumoniae antigen in sputum samples from patients with lower respiratory tract infection.

نویسندگان

  • Koichi Izumikawa
  • Suguru Akamatsu
  • Akiko Kageyama
  • Kiyomi Okada
  • Yukumasa Kazuyama
  • Noboru Takayanagi
  • Shigeki Nakamura
  • Yuichi Inoue
  • Yasuhito Higashiyama
  • Kiyoyasu Fukushima
  • Tadashi Ishida
  • Toyomitsu Sawai
  • Kunihiko Yoshimura
  • Chikara Nakahama
  • Mitsuhide Ohmichi
  • Tomoyuki Kakugawa
  • Yasuhiko Nishioka
  • Nobuki Aoki
  • Masafumi Seki
  • Hiroshi Kakeya
  • Yoshihiro Yamamoto
  • Katsunori Yanagihara
  • Shigeru Kohno
چکیده

A novel, rapid, and noninvasive test (ODK0501) to detect Streptococcus pneumoniae antigen was evaluated in a Japanese multicenter study. ODK0501 uses polyclonal antibodies to detect C polysaccharide of S. pneumoniae from sputum samples by an immunochromatographic assay. The utility of ODK0501 was evaluated for 161 adult patients with lower respiratory tract infection between March 2006 and March 2007. Bacterial culture and identification, real-time PCR, and ODK0501 assays were performed on sputum samples, and the Binax Now Streptococcus pneumoniae antigen test was performed using urine samples obtained from the same patients. The performances of all tests were compared based on the results of bacterial culture and identification. The sensitivity and specificity of ODK0501 were 89.1% (49/55 samples) and 95.3% (101/106 samples), respectively. We then compared the Binax Now Streptococcus pneumoniae antigen test with ODK0501 using samples from 142 patients. The sensitivities of ODK0501 and the Binax Now S. pneumoniae antigen test were 90.0% (45/50 samples) and 62.0% (31/50 samples), respectively (P = 0.002). The relative quantity of S. pneumoniae in expectorated sputum was calculated using real-time PCR and indicated that the possibility of false-positive results for ODK0501 due to indigenous S. pneumoniae was low. The positive and negative concordance rates of ODK0501 and Binax Now were 96.8% (30/31 samples) and 21.1% (4/19 samples), respectively. Binax Now was less capable of detecting S. pneumoniae antigen among patients with underlying chronic obstructive pulmonary disease. In conclusion, ODK0501 is noninvasive, rapid, and an accurate tool for diagnosing respiratory infection caused by S. pneumoniae.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a rapid immunochromatographic ODK0501 assay for detecting Streptococcus pneumoniae antigen in sputum from patients with lower respiratory tract infection Running title: Detecting S. pneumoniae antigen in sputum

Author(s) Izumikawa, Koichi; Akamatsu, Suguru; Kageyama, Akiko; Okada, Kiyomi; Kazuyama, Yukumasa; Takayanagi, Noboru; Nakamura, Shigeki; Inoue, Yuichi; Higashiyama, Yasuhito; Fukushima, Kiyoyasu; Ishida, Tadashi; Sawai, Toyomitsu; Yoshimura, Kunihiko; Nakahama, Chikara; Ohmichi, Mitsuhide; Kakugawa, Tomoyuki; Nishioka, Yasuhiko; Aoki, Nobuki; Seki, Masafumi; Kakeya, Hiroshi; Yamamoto, Yoshihir...

متن کامل

Evaluation of the rapid immunochromatographic ODK0501 assay for Streptococcus pneumoniae antigen detection with nasopharyngeal swabs: preliminary report

BACKGROUND Early identification and control of pathogenic bacteria are important in the treatment of pneumonia. Currently, two rapid antigen detection kits for pneumococcal pneumonia are available: one uses urine samples and the other, named RAPIRUN® S. pneumoniae, uses sputum samples. RAPIRUN® has shown high sensitivity with nasopharyngeal swab samples from pediatric patients. In this study, w...

متن کامل

باکتری های پاتوژن جدا شده از نمونه بیماران مشکوک به عفونت ریوی

The lower respiratory tract is vulnerable to infection by a wide variety of microorganisms, because it is one of the organ systems which communicate directly with the environments. Although viruses and fungi can cause lower respiratory tract infections, bacteria are the dominant pathogens. Among bacteria the common causes of lower respiratory tract infection is Streptococcus pneumoniae, Mycopla...

متن کامل

Characteristics of Streptococcus pseudopneumoniae isolated from purulent sputum samples.

Streptococcus pseudopneumoniae is a recently described streptococcus that is phenotypically and genetically distinct from Streptococcus pneumoniae and other viridans streptococci. Key characteristics of S. pseudopneumoniae are the absence of a pneumococcal capsule, insolubility in bile, resistance or indeterminate susceptibility to optochin when incubated in 5% CO2 but susceptibility to optochi...

متن کامل

Assessment of a rapid immunochromatographic assay for the detection of avian influenza viruses

Rapid spreading of the low pathogenic avian influenza virus (AIV) caused by the H9N2 subtype and the highly pathogenic AIV caused by H5N1 have caused serious economic losses in the poultry industries of Asia. Therefore, the early detection of AIVs is crucial for the control of the disease. In the present study, the applicability of a rapid immunochromatographic (RIC) assay, which specifically d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and vaccine immunology : CVI

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2009