Optimization and validation of a GC-FID method for the determination of acetone-butanol-ethanol fermentation products.

نویسندگان

  • Xiaoqing Lin
  • Jiansheng Fan
  • Qingshi Wen
  • Renjie Li
  • Xiaohong Jin
  • Jinglan Wu
  • Wenbin Qian
  • Dong Liu
  • Jingjing Xie
  • Jianxin Bai
  • Hanjie Ying
چکیده

An improved, simple gas chromatography-flame ionization detection (GC-FID) method was developed for measuring the products of acetone-butanol-ethanol (ABE) fermentation and the combined fermentation/separation processes. The analysis time per sample was reduced to less than 10 min compared to those of a conventional GC-FID (more than 20 min). The behavior of the compounds in temperature-programmed gas chromatographic runs was predicted using thermodynamic parameters derived from isothermal runs. The optimum temperature programming condition was achieved when the resolution for each peak met the analytical requirement and the analysis time was shortest. With the exception of acetic acid, the detection limits of the presented method for various products were below 10 mg/L. The repeatability and intermediate precision of the method were less than 10% (relative standard deviation). Validation and quantification results demonstrated that this method is a sensitive, reliable and fast alternative for conventional investigation of the adsorption-coupled ABE fermentation process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid and Simultaneous Determination of Acetone, Butanol and Ethanol in Butanol Fermentation Broth by Full Evaporation Headspace Gas Chromatography

A gas chromatography (GC) method including a full evaporation headspace (FE-HS) sampling technique was developed for rapidly and simultaneously measuring volatile products for acetone-butanol-ethanol (ABE) fermentation. In this method, a small volume (<50 μL) of fermentation broth was directly injected into a sealed headspace sample vial (22 mL) and the mass transfer of acetone-butanol-ethanol ...

متن کامل

Investigation of Behavior of Forced Degradation of Lidocaine HCl by NMR Spectroscopy and GC-FID Methods: Validation of GC-FID Method for Determination of Related Substance in Pharmaceutical Formulations

  The forced degradation study of lidocaine HCl was carried out according to the ICH guideline Q1A (R2). The degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by GC-FID method and nuclear magnetic resonance (NMR) spectroscopy. According to these results, the degradation products were not o...

متن کامل

Investigation of Behavior of Forced Degradation of Lidocaine HCl by NMR Spectroscopy and GC-FID Methods: Validation of GC-FID Method for Determination of Related Substance in Pharmaceutical Formulations

  The forced degradation study of lidocaine HCl was carried out according to the ICH guideline Q1A (R2). The degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by GC-FID method and nuclear magnetic resonance (NMR) spectroscopy. According to these results, the degradation products were not o...

متن کامل

Development and Validation of a GC-FID Method for Diagnosis of Methylmalonic Acidemia

Background: Urinary organic acids are water-soluble intermediates and end products of the metabolism of amino acids, carbohydrates, lipids, and a number of other metabolic processes. In the hereditary diseases known as organic acidurias, an enzyme or co-factor defect in a metabolic pathway leads to the accumulation and increased excretion of one or more of these acidic metabolites. Gas chromato...

متن کامل

Development and validation of GC-FID method for the determination of ethanol residue in marjoram ointment.

Our study describes the procedure development and validation of the GC-FID method for the determination of ethanol content in marjoram ointment. At the validation procedure linearity ranged from 1 x 10(-4)% to 1 x 10(-1)%, limit of detection was 5 x 10(-5)%, relative standard deviation for precision RSD = 1.07%, relative standard deviation for intermediate precision RSD = 1.43% and good recover...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2014