An investigation into the effects of excipient particle size, blending techniques and processing parameters on the homogeneity and content uniformity of a blend containing low-dose model drug

نویسندگان

  • Hamad Alyami
  • Eman Dahmash
  • James Bowen
  • Afzal R Mohammed
چکیده

Powder blend homogeneity is a critical attribute in formulation development of low dose and potent active pharmaceutical ingredients (API) yet a complex process with multiple contributing factors. Excipient characteristics play key role in efficient blending process and final product quality. In this work the effect of excipient type and properties, blending technique and processing time on content uniformity was investigated. Powder characteristics for three commonly used excipients (starch, pregelatinised starch and microcrystalline cellulose) were initially explored using laser diffraction particle size analyser, angle of repose for flowability, followed by thorough evaluations of surface topography employing scanning electron microscopy and interferometry. Blend homogeneity was evaluated based on content uniformity analysis of the model API, ergocalciferol, using a validated analytical technique. Flowability of powders were directly related to particle size and shape, while surface topography results revealed the relationship between surface roughness and ability of excipient with high surface roughness to lodge fine API particles within surface groves resulting in superior uniformity of content. Of the two blending techniques, geometric blending confirmed the ability to produce homogeneous blends at low dilution when processed for longer durations, whereas manual ordered blending failed to achieve compendial requirement for content uniformity despite mixing for 32 minutes. Employing the novel dry powder hybrid mixer device, developed at Aston University laboratory, results revealed the superiority of the device and enabled the production of homogenous blend irrespective of excipient type and particle size. Lower dilutions of the API (1% and 0.5% w/w) were examined using non-sieved excipients and the dry powder hybrid mixing device enabled the development of successful blends within compendial requirements and low relative standard deviation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of process parameters on content uniformity of a low dose active pharmaceutical ingredient in a tablet formulation according to GMP.

The article describes the development and production of tablets using direct compression of powder mixtures. The aim was to describe the impact of filler particle size and the time of lubricant addition during mixing on content uniformity according to the Good Manufacturing Practice (GMP) process validation requirements. Processes are regulated by complex directives, forcing the producers to va...

متن کامل

Evaluation of the effect of granulation processing parameters on the granule properties: Lactose- Cornstarch case study

Understanding the relationship between processing parameters of fluidized bed wet granulation and the characteristics of intermediate and final products is crucial in the pharmaceutical processes. This research examined a fluidized bed wet granulation process containing a cornstarch solution as binder and lactose particles as powder. The design of experiment (DoE) was performed according to an ...

متن کامل

Agglomeration Tendency in Dry Pharmaceutical Granular Systems During Blending: De-Agglomeration Modeling Approaches

Efficient blending of powders is of critical importance in the manufacture of a wide variety of industrial products, including pharmaceuticals, foods, plastics and agrochemicals [1, 2]. This study determined the influence of geometry of blenders (double cone blender and V-blender), blending speed and time. The blend composed of diclofenac sodium, lactose, magnesium stearate and talc. It was sub...

متن کامل

Effect of drug particle size on content uniformity of low-dose solid dosage forms

Two low-dose blends were prepared that differed only in the particle size of the drug used to make the blends. The geometric mean particle diameters for the two lots of drug used were 18.5 and 6.1 /~m. Samples of the blends approximately equivalent to the unit dose of 10 /~g per 99 mg of blend were assayed for potency. For the blend containing the larger particle size drug, the potency range wa...

متن کامل

Characterizing films of polyethylene blends: An application of colorimetric parameters measurements

This study reports an application of instrumental color measurement for quantifying and comparing the optical properties of high density polyethylene HDPE and low density polyethylene LDPE blend films and the effect of blending ratio and miscibility on these properties. The technique of spectrophotometry in transmission and reflectance modes can be used as a versatile tool to evaluate the color...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017